Back to Search Start Over

A pre-clinical validation plan to evaluate analytical sensitivities of molecular diagnostics such as BD MAX MDR-TB, Xpert MTB/Rif Ultra and FluoroType MTB.

Authors :
Markus Beutler
Sara Plesnik
Marina Mihalic
Laura Olbrich
Norbert Heinrich
Samuel Schumacher
Michael Lindner
Ina Koch
Wolfgang Grasse
Christoph Metzger-Boddien
Sabine Hofmann-Thiel
Harald Hoffmann
Source :
PLoS ONE, Vol 15, Iss 1, p e0227215 (2020)
Publication Year :
2020
Publisher :
Public Library of Science (PLoS), 2020.

Abstract

Rapid diagnosis of tuberculosis (TB) and antibiotic resistances are imperative to initiate effective treatment and to stop transmission of the disease. A new generation of more sensitive, automated molecular TB diagnostic tests has been recently launched giving microbiologists more choice between several assays with the potential to detect resistance markers for rifampicin and isoniazid. In this study, we determined analytical sensitivities as 95% limits of detection (LoD95) for Xpert MTB/Rif Ultra (XP-Ultra) and BD-MAX MDR-TB (BD-MAX) as two representatives of the new test generation, in comparison to the conventional FluoroType MTB (FT-MTB). Test matrices used were physiological saline solution, human and a mucin-based artificial sputum (MUCAS) each spiked with Mycobacterium tuberculosis in declining culture- and qPCR-controlled concentrations. With BD-MAX, XP-Ultra, and FT-MTB, we measured LoD95TB values of 2.1 cfu/ml (CI95%: 0.9-23.3), 3.1 cfu/ml (CI95%: 1.2-88.9), and 52.1 cfu/ml (CI95%: 16.7-664.4) in human sputum; of 6.3 cfu/ml (CI95%: 2.9-31.8), 1.5 cfu/ml (CI95%: 0.7-5.0), and 30.4 cfu/ml (CI95%: 17.4-60.7) in MUCAS; and of 2.3 cfu/ml (CI95%: 1.1-12.0), 11.5 cfu/ml (CI95%: 5.6-47.3), and 129.1 cfu/ml (CI95%: 82.8-273.8) in saline solution, respectively. LoD95 of resistance markers were 9 to 48 times higher compared to LoD95TB. BD-MAX and XP-Ultra have an equal and significantly increased analytical sensitivity compared to conventional tests. MUCAS resembled human sputum, while both yielded significantly different results than normal saline. MUCAS proved to be suitable for quality control of PCR assays for TB diagnostics.

Subjects

Subjects :
Medicine
Science

Details

Language :
English
ISSN :
19326203
Volume :
15
Issue :
1
Database :
Directory of Open Access Journals
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
edsdoj.f076607e98f14880afc9b7b055383d6c
Document Type :
article
Full Text :
https://doi.org/10.1371/journal.pone.0227215