Back to Search Start Over

Frugal and Translatable [15O]O2 Production for Human Inhalation with Direct Delivery from the Cyclotron to a Hybrid PET/MR

Authors :
Jeffrey Corsaut
Elmer Soto
Heather Biernaski
Michael S. Kovacs
Keith St. Lawrence
Justin W. Hicks
Source :
Diagnostics, Vol 14, Iss 9, p 902 (2024)
Publication Year :
2024
Publisher :
MDPI AG, 2024.

Abstract

Oxygen-15 (β+, t1/2 = 122 s) radiolabeled diatomic oxygen, in conjunction with positron emission tomography, is the gold standard to quantitatively measure the metabolic rate of oxygen consumption in the living human brain. We present herein a protocol for safe and effective delivery of [15O]O2 over 200 m to a human subject for inhalation. A frugal quality control testing procedure was devised and validated. This protocol can act as a blueprint for other sites seeking to implement similar imaging programs.