Back to Search Start Over

Three-Dimensional Quantitative Assessment of Pedicle Screw Accuracy in Clinical Utilization of a New Robotic System in Spine Surgery: A Multicenter Study

Authors :
Byeong-Jin Ha
Jong-Min Lee
Seon-Jin Yoon
Byung-Kwan Kim
Junseok Lee
Suhun Lee
Seungjae Ryu
Yongyeob Cha
Sungteac Hwang
Donggi Woo
Chang Kyu Lee
Dong Ah Shin
Yoon Ha
Sung Uk Kuh
Keung Nyun Kim
Dongwuk Son
Seong Yi
Source :
Neurospine, Vol 20, Iss 3, Pp 1028-1039 (2023)
Publication Year :
2023
Publisher :
Korean Spinal Neurosurgery Society, 2023.

Abstract

Objective The objective of this study was to evaluate the accuracy of pedicle screw placement in patients undergoing percutaneous pedicle screw fixation with robotic guidance, using a newly developed 3-dimensional quantitative measurement system. The study also aimed to assess the clinical feasibility of the robotic system in the field of spinal surgery. Methods A total of 113 patients underwent pedicle screw insertion using the CUVIS-spine pedicle screw guide system (CUREXO Inc.). Intraoperative O-arm images were obtained, and screw insertion pathways were planned accordingly. Image registration was performed using paired-point registration and iterative closest point methods. The accuracy of the robotic-guided pedicle screw insertion was assessed using 3-dimensional offset calculation and the Gertzbein-Robbins system (GRS). Results A total of 448 screws were inserted in the 113 patients. The image registration success rate was 95.16%. The average error of entry offset was 2.86 mm, target offset was 2.48 mm, depth offset was 1.99 mm, and angular offset was 3.07°. According to the GRS grading system, 88.39% of the screws were classified as grade A, 9.60% as grade B, 1.56% as grade C, 0.22% as grade D, and 0.22% as grade E. Clinically acceptable screws (GRS grade A or B) accounted for 97.54% of the total, with no reported neurologic complications. Conclusion Our study demonstrated that pedicle screw insertion using the novel robot-assisted navigation method is both accurate and safe. Further prospective studies are necessary to explore the potential benefits of this robot-assisted technique in comparison to conventional approaches.

Details

Language :
English
ISSN :
25866583 and 25866591
Volume :
20
Issue :
3
Database :
Directory of Open Access Journals
Journal :
Neurospine
Publication Type :
Academic Journal
Accession number :
edsdoj.bbd52ff5d6cb4fb6a45e2a33cbef3b39
Document Type :
article
Full Text :
https://doi.org/10.14245/ns.2346552.276