Back to Search Start Over

Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance

Authors :
Sophia Houriez--Gombaud-Saintonge
Elie Mousseaux
Ioannis Bargiotas
Alain De Cesare
Thomas Dietenbeck
Kevin Bouaou
Alban Redheuil
Gilles Soulat
Alain Giron
Umit Gencer
Damian Craiem
Emmanuel Messas
Emilie Bollache
Yasmina Chenoune
Nadjia Kachenoura
Source :
Journal of Cardiovascular Magnetic Resonance, Vol 21, Iss 1, Pp 1-13 (2019)
Publication Year :
2019
Publisher :
Elsevier, 2019.

Abstract

Abstract Background Arterial pulse wave velocity (PWV) is associated with increased mortality in aging and disease. Several studies have shown the accuracy of applanation tonometry carotid-femoral PWV (Cf-PWV) and the relevance of evaluating central aorta stiffness using 2D cardiovascular magnetic resonance (CMR) to estimate PWV, and aortic distensibility-derived PWV through the theoretical Bramwell-Hill model (BH-PWV). Our aim was to compare various methods of aortic PWV (aoPWV) estimation from 4D flow CMR, in terms of associations with age, Cf-PWV, BH-PWV and left ventricular (LV) mass-to-volume ratio while evaluating inter-observer reproducibility and robustness to temporal resolution. Methods We studied 47 healthy subjects (49.5 ± 18 years) who underwent Cf-PWV and CMR including aortic 4D flow CMR as well as 2D cine SSFP for BH-PWV and LV mass-to-volume ratio estimation. The aorta was semi-automatically segmented from 4D flow data, and mean velocity waveforms were estimated in 25 planes perpendicular to the aortic centerline. 4D flow CMR aoPWV was calculated: using velocity curves at two locations, namely ascending aorta (AAo) and distal descending aorta (DAo) aorta (S1, 2D-like strategy), or using all velocity curves along the entire aortic centreline (3D-like strategies) with iterative transit time (TT) estimates (S2) or a plane fitting of velocity curves systolic upslope (S3). For S1 and S2, TT was calculated using three approaches: cross-correlation (TTc), wavelets (TTw) and Fourier transforms (TTf). Intra-class correlation coefficients (ICC) and Bland-Altman biases (BA) were used to evaluate inter-observer reproducibility and effect of lower temporal resolution. Results 4D flow CMR aoPWV estimates were significantly (p

Details

Language :
English
ISSN :
1532429X
Volume :
21
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Journal of Cardiovascular Magnetic Resonance
Publication Type :
Academic Journal
Accession number :
edsdoj.bac48fa6f57e4ab796e89d4452e9645d
Document Type :
article
Full Text :
https://doi.org/10.1186/s12968-019-0584-x