Back to Search Start Over

SAFIR-I: Design and Performance of a High-Rate Preclinical PET Insert for MRI

Authors :
Pascal Bebié
Robert Becker
Volker Commichau
Jan Debus
Günther Dissertori
Lubomir Djambazov
Afroditi Eleftheriou
Jannis Fischer
Peter Fischer
Mikiko Ito
Parisa Khateri
Werner Lustermann
Christian Ritzer
Michael Ritzert
Ulf Röser
Charalampos Tsoumpas
Geoffrey Warnock
Bruno Weber
Matthias T. Wyss
Agnieszka Zagozdzinska-Bochenek
Source :
Sensors, Vol 21, Iss 21, p 7037 (2021)
Publication Year :
2021
Publisher :
MDPI AG, 2021.

Abstract

(1) Background: Small Animal Fast Insert for MRI detector I (SAFIR-I) is a preclinical Positron Emission Tomography (PET) insert for the Bruker BioSpec 70/30 Ultra Shield Refrigerated (USR) preclinical 7T Magnetic Resonance Imaging (MRI) system. It is designed explicitly for high-rate kinetic studies in mice and rats with injected activities reaching 500MBq, enabling truly simultaneous quantitative PET and Magnetic Resonance (MR) imaging with time frames of a few seconds in length. (2) Methods: SAFIR-I has an axial field of view of 54.2mm and an inner diameter of 114mm. It employs Lutetium Yttrium OxyorthoSilicate (LYSO) crystals and Multi Pixel Photon Counter (MPPC) arrays. The Position-Energy-Timing Application Specific Integrated Circuit, version 6, Single Ended (PETA6SE) digitizes the MPPC signals and provides time stamps and energy information. (3) Results: SAFIR-I is MR-compatible. The system’s Coincidence Resolving Time (CRT) and energy resolution are between separate-uncertainty 209.0(3)ps and separate-uncertainty 12.41(02) Full Width at Half Maximum (FWHM) at low activity and separate-uncertainty 326.89(12)ps and separate-uncertainty 20.630(011) FWHM at 550MBq, respectively. The peak sensitivity is ∼1.6. The excellent performance facilitated the successful execution of first in vivo rat studies beyond 300MBq. Based on features visible in the acquired images, we estimate the spatial resolution to be ∼2mm in the center of the Field Of View (FOV). (4) Conclusion: The SAFIR-I PET insert provides excellent performance, permitting simultaneous in vivo small animal PET/MR image acquisitions with time frames of a few seconds in length at activities of up to 500MBq.

Details

Language :
English
ISSN :
14248220
Volume :
21
Issue :
21
Database :
Directory of Open Access Journals
Journal :
Sensors
Publication Type :
Academic Journal
Accession number :
edsdoj.ba9e9aee12a44992b33bddae47aa4c21
Document Type :
article
Full Text :
https://doi.org/10.3390/s21217037