Comparative clinical accuracy analysis of the newly developed ZZ IOL and four existing IOL formulas for post-corneal refractive surgery eyes
- Source :
- BMC Ophthalmology, Vol 21, Iss 1, Pp 1-9 (2021)
- Publication Year :
- 2021
- Publisher :
- BMC, 2021.
-
Abstract
- Abstract Background Intraocular lens (IOL) calculation using traditional formulas for post-corneal refractive surgery eyes can yield inaccurate results. This study aimed to compare the clinical accuracy of the newly developed Zhang & Zheng (ZZ) formula with previously reported IOL formulas. Study design Retrospective study. Methods Post-corneal refractive surgery eyes were assessed for IOL power using the ZZ, Haigis-L, Shammas, Barrett True-K (no history), and ray tracing (C.S.O Sirius) IOL formulas, and their accuracy was compared. No pre-refractive surgery information was used in the calculations. Results This study included 38 eyes in 26 patients. ZZ IOL yielded a lower arithmetic IOL prediction error (PE) compared with ray tracing (P = 0.04), whereas the other formulas had values like that of ZZ IOL (P > 0.05). The arithmetic IOL PE for the ZZ IOL formula was not significantly different from zero (P = 0.96). ZZ IOL yielded a lower absolute IOL PE compared with Shammas (P
Details
- Language :
- English
- ISSN :
- 14712415
- Volume :
- 21
- Issue :
- 1
- Database :
- Directory of Open Access Journals
- Journal :
- BMC Ophthalmology
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.ba6fd1e50126468b99ecc188dad2688a
- Document Type :
- article
- Full Text :
- https://doi.org/10.1186/s12886-021-01991-7