One-Year Outcomes after Surgical versus Transcatheter Aortic Valve Replacement with Newer Generation Devices

Authors :
Stefano Rosato
Fausto Biancari
Paola D’Errigo
Marco Barbanti
Giuseppe Tarantini
Francesco Bedogni
Marco Ranucci
Giuliano Costa
Tatu Juvonen
Gian Paolo Ussia
Andrea Marcellusi
Giovanni Baglio
Stefano Domenico Cicala
Gabriella Badoni
Fulvia Seccareccia
Corrado Tamburino
on behalf of the OBSERVANT II Research Group
Source :
Journal of Clinical Medicine, Vol 10, Iss 16, p 3703 (2021)
Publication Year :
2021
Publisher :
MDPI AG, 2021.

Abstract

The superiority of transcatheter (TAVR) over surgical aortic valve replacement (SAVR) for severe aortic stenosis (AS) has not been fully demonstrated in a real-world setting. This prospective study included 5706 AS patients who underwent SAVR from 2010 to 2012 and 2989 AS patients who underwent TAVR from 2017 to 2018 from the prospective multicenter observational studies OBSERVANT I and II. Early adverse events as well as all-cause mortality, major adverse cardiac and cerebrovascular events (MACCEs), and hospital readmission due to heart failure at 1-year were investigated. Among 1008 propensity score matched pairs, TAVR was associated with significantly lower 30-day mortality (1.8 vs. 3.5%, p = 0.020), stroke (0.8 vs. 2.3%, p = 0.005), and acute kidney injury (0.6 vs. 8.2%, p < 0.001) compared to SAVR. Moderate-to-severe paravalvular regurgitation (5.9 vs. 2.0%, p < 0.001) and permanent pacemaker implantation (13.8 vs. 3.3%, p < 0.001) were more frequent after TAVR. At 1-year, TAVR was associated with lower risk of all-cause mortality (7.9 vs. 11.5%, p = 0.006), MACCE (12.0 vs. 15.8%, p = 0.011), readmission due to heart failure (10.8 vs. 15.9%, p < 0.001), and stroke (3.2 vs. 5.1%, p = 0.033) compared to SAVR. TAVR reduced 1-year mortality in the subgroups of patients aged 80 years or older (HR 0.49, 95% CI 0.33–0.71), in females (HR 0.57, 0.38–0.85), and among patients with EuroSCORE II ≥ 4.0% (HR 0.48, 95% CI 0.32–0.71). In a real-world setting, TAVR using new-generation devices was associated with lower rates of adverse events up to 1-year follow-up compared to SAVR.

Details

Language :
English
ISSN :
20770383
Volume :
10
Issue :
16
Database :
Directory of Open Access Journals
Journal :
Journal of Clinical Medicine
Publication Type :
Academic Journal
Accession number :
edsdoj.b8e8b989feec4d9daa139442f85ce484
Document Type :
article
Full Text :
https://doi.org/10.3390/jcm10163703