Abstract

Warfarin (WF) is an anticoagulant commonly used for thromboembolism-related diseases.This study aims to assess the pharmacokinetic profile of WF. The stereospecific interaction of S-and R-WF requires quantification of the enantiomer to determine the pharmacokinetic profile. The analysis method of the enantiomers in plasma is developed using an HPLC fluorescence detector with a Chiralcel OD-RH column (4.6 mm × 150 mm i.d., 5 m) and a Chiralcel OD-RH guard column (4.0 mm × 10 mm, 5 m). The separation is conducted using isocratic with acetonitrile mobile phase: Phosphate buffer, pH 2.00 (40:60 v/v), column temperature 40°C, flow rate 1 mL/min, injection volume 50 L. WF is measured at an excitation wavelength of 310 nm and emission of 350 nm. This method results in limit of detection (LOD) values of 18.6 ng/mL and limit of quantitation (LOQ) of 62.01 ng/mL for R-WF and LOD values of 18.61 ng/mL and LOQ of 62.04 ng/mL for S-WF. The results showed a linearity in concentration between 100 and 2500 ng/mL with r2 = 0.9969 and r2 = 0.9991 for R-and S-WF. The validation requirements of selectivity, accuracy, and precision for within and between run with a value of

Details

Language :
English
ISSN :
22314040 and 09762094
Volume :
13
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Journal of Advanced Pharmaceutical Technology & Research
Publication Type :
Academic Journal
Accession number :
edsdoj.b7eb791f4041a09b1b27d8534125b0
Document Type :
article
Full Text :
https://doi.org/10.4103/japtr.japtr_259_21