Back to Search Start Over

Field Test of the MiniRadMeter Gamma and Neutron Detector for the EU Project CLEANDEM

Authors :
Marco Ripani
Fabio Rossi
Luigi Cosentino
Fabio Longhitano
Paolo Musico
Mikhail Osipenko
Gaetano Elio Poma
Paolo Finocchiaro
Source :
Sensors, Vol 24, Iss 18, p 5905 (2024)
Publication Year :
2024
Publisher :
MDPI AG, 2024.

Abstract

In the framework of the H2020 CLEANDEM project, a small robotic vehicle was equipped with a series of different sensors that were developed for the preliminary inspection of areas possibly contaminated by radiation. Such unmanned inspection allows to identify dangerous locations prior to the possible start of human operations. One of the developed devices, named the MiniRadMeter, is a compact low-cost sensor that performs gamma and neutron radiation field mapping in the environment. The MiniRadMeter was successfully tested in a simulated field mission with four “hidden” radioactive sources and a neutron generator. In this work, we describe the test procedure and the results, which were supported by the outcome of dedicated Monte Carlo simulations.

Details

Language :
English
ISSN :
14248220
Volume :
24
Issue :
18
Database :
Directory of Open Access Journals
Journal :
Sensors
Publication Type :
Academic Journal
Accession number :
edsdoj.b553553b55e149428f8c17d19c740b13
Document Type :
article
Full Text :
https://doi.org/10.3390/s24185905