Back to Search Start Over

Role of abbreviated non-contrast-enhanced MR-enterography in the evaluation of Crohn's disease activity and complications as an alternative for full protocol contrast-enhanced study: A systematic review and meta-analysis

Authors :
Payam Jannatdoust
Parya Valizadeh
Mahshad Razaghi
Maedeh Rouzbahani
Amirbahador Abbasi
Arvin Arian
Source :
Research in Diagnostic and Interventional Imaging, Vol 6, Iss , Pp 100030- (2023)
Publication Year :
2023
Publisher :
Elsevier, 2023.

Abstract

Background: Crohn's disease (CD) is a chronic disorder that often starts at a young age and involves periods of remission and relapse. Prompt diagnosis of relapses through screening is crucial due to the potential morbid complications of untreated active inflammation. Magnetic resonance enterography (MRE) is a noninvasive technique to screen for active inflammation. The standard protocol involves intravenous injection of contrast agents with potential side effects. Some abbreviated non-contrast-enhanced MRE protocols are proposed as alternatives for conventional MRE to identify active inflammation. Currently, there is controversy regarding the applicability and accuracy of these protocols. This study aims to describe and compare these protocols and evaluate their accuracy in detecting active inflammation and CD complications. Methods: Results from a systematic search of three databases in August 2022 were queried and screened by abstract and full text. Eligible studies were qualitatively and quantitatively analyzed by diagnostic test accuracy meta-analysis. Results: 59 studies entered the systematic review, and 37 were eligible for meta-analysis. Diffusion-weighted imaging (DWI) and fast T2-weighted (T2w) sequences were most frequently used in abbreviated protocols and showed non-inferior accuracy compared to the full protocol in detecting active inflammation. ADC and qualitative DWI had pooled sensitivity of 90% (CI: 82–95%) and 89% (CI:82–93%) and pooled specificity of 94% (CI: 88–97%) and 89% (CI: 79–94%), respectively for detecting active inflammation. Moreover, T2w and combined T2w+DWI sequences had pooled sensitivity of 80% (CI: 64–90%) and 76% (CI: 61–86%) and pooled specificity of 90% (CI: 80–95%) and 87% (CI: 74 – 94%), respectively. Unenhanced protocols show relatively poor diagnostic accuracy in detecting penetrating complications of CD. Magnetization transfer imaging (MTI) has demonstrated excellent accuracy in detecting fibrosis. High heterogeneity was observed in all subgroups, and accuracy was reported to be highly operator dependent in most studies. Conclusion: An abbreviated protocol consisting of DWI and fast T2w imaging can potentially replace the full protocol MRE. Full protocol MRE will still have its role in identifying penetrating complications. MTI should be indicated in case of suspected fibrostenotic disease.

Details

Language :
English
ISSN :
27726525
Volume :
6
Issue :
100030-
Database :
Directory of Open Access Journals
Journal :
Research in Diagnostic and Interventional Imaging
Publication Type :
Academic Journal
Accession number :
edsdoj.b4db561e5894ac7a5f55055dd658185
Document Type :
article
Full Text :
https://doi.org/10.1016/j.redii.2023.100030