Characterization of Diamond and Silicon Carbide Detectors With Fission Fragments

Authors :
M. L. Gallin-Martel
Y. H. Kim
L. Abbassi
A. Bes
C. Boiano
S. Brambilla
J. Collot
G. Colombi
T. Crozes
S. Curtoni
D. Dauvergne
C. Destouches
F. Donatini
L. Gallin-Martel
O. Ghouini
J. Y. Hostachy
Ł. W. Iskra
M. Jastrzab
G. Kessedjian
U. Köster
A. Lacoste
A. Lyoussi
S. Marcatili
J. F. Motte
J. F. Muraz
T. Nowak
L. Ottaviani
J. Pernot
A. Portier
W. Rahajandraibe
M. Ramdhane
M. Rydygier
C. Sage
A. Tchoualack
L. Tribouilloy
M. Yamouni
Source :
Frontiers in Physics, Vol 9 (2021)
Publication Year :
2021
Publisher :
Frontiers Media S.A., 2021.

Abstract

Experimental fission studies for reaction physics or nuclear spectroscopy can profit from fast, efficient, and radiation-resistant fission fragment (FF) detectors. When such experiments are performed in-beam in intense thermal neutron beams, additional constraints arise in terms of target-detector interface, beam-induced background, etc. Therefore, wide gap semi-conductor detectors were tested with the aim of developing innovative instrumentation for such applications. The detector characterization was performed with mass- and energy-separated fission fragment beams at the ILL (Institut Laue Langevin) LOHENGRIN spectrometer. Two single crystal diamonds, three polycrystalline and one diamond-on-iridium as well as a silicon carbide detector were characterized as solid state ionization chamber for FF detection. Timing measurements were performed with a 500-µm thick single crystal diamond detector read out by a broadband amplifier. A timing resolution of ∼10.2 ps RMS was obtained for FF with mass A = 98 at 90 MeV kinetic energy. Using a spectroscopic preamplifier developed at INFN-Milano, the energy resolution measured for the same FF was found to be slightly better for a ∼50-µm thin single crystal diamond detector (∼1.4% RMS) than for the 500-µm thick one (∼1.6% RMS), while a value of 3.4% RMS was obtained with the 400-µm silicon carbide detector. The Pulse Height Defect (PHD), which is significant in silicon detectors, was also investigated with the two single crystal diamond detectors. The comparison with results from α and triton measurements enabled us to conclude that PHD leads to ∼50% loss of the initial generated charge carriers for FF. In view of these results, a possible detector configuration and integration for in-beam experiments has been discussed.

Details

Language :
English
ISSN :
2296424X
Volume :
9
Database :
Directory of Open Access Journals
Journal :
Frontiers in Physics
Publication Type :
Academic Journal
Accession number :
edsdoj.b3c2b73689464227905f2c2c574be194
Document Type :
article
Full Text :
https://doi.org/10.3389/fphy.2021.732730