Back to Search
Start Over
Undilated versus dilated monoscopic smartphone-based fundus photography for optic nerve head evaluation
- Source :
- Scientific Reports, Vol 8, Iss 1, Pp 1-7 (2018)
- Publication Year :
- 2018
- Publisher :
- Nature Portfolio, 2018.
-
Abstract
- Abstract Smartphone-based fundus photography (SBFP) allows for a cheap and mobile fundus examination with the potential to revolutionize eye care especially in low income settings. The purpose of this study was to assess the impact of pupil dilation on image quality in optic nerve head (ONH) imaging and vertical cup-to-disc ratio (vCDR) evaluation with SBFP. Eyes with glaucoma or suspected to have glaucoma were imaged with conventional digital fundus photography (CFP) and SBFP undilated and following dilation, all monoscopically. SBFP was possible in 74% of eyes without dilation and in 98% following dilation. Better image quality on SBFP was achieved with dilation and complete visualization of the optic disc rim was possible in 46% of images without dilation and on 94% of images with dilation. VCDR measurements on images obtained following dilation highly correlated with measurements on CFP (coefficient of correlation r = 0.91, p
Details
- Language :
- English
- ISSN :
- 20452322
- Volume :
- 8
- Issue :
- 1
- Database :
- Directory of Open Access Journals
- Journal :
- Scientific Reports
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.b0836fe4b8fd48338f69878e659a46a2
- Document Type :
- article
- Full Text :
- https://doi.org/10.1038/s41598-018-28585-6