Back to Search
Start Over
Point-of-Care Ultrasound (POCUS) for the assessment of volume status and fluid management in patients with severe pre-eclampsia: A systematic review and meta-analysis
- Source :
- Indian Journal of Anaesthesia, Vol 65, Iss 10, Pp 716-730 (2021)
- Publication Year :
- 2021
- Publisher :
- Wolters Kluwer Medknow Publications, 2021.
-
Abstract
- Background and Aims: Appropriate volume assessment and fluid management can prevent maternal deaths in the severely pre-eclamptic (SPE) parturients. We planned a systematic review and meta-analysis (MA) to evaluate the role and ability of point-of-care ultrasound (POCUS) in the assessment of volume status and early detection of lung oedema in an SPE parturient. Methods: An e-literature search was done from several databases. Data were extracted under five domains including POCUS-derived parameters like echo comet score (ECS), lung ultrasound (LUS) scores, B-patterns, optic nerve sheath diameter (ONSD), E/e' ratio, presence of pleural effusion, pulmonary interstitial syndrome and pulmonary congestion. The risk of bias was assessed. Extracted data were analysed using MetaXL and Revman 5.3. Heterogeneity in the studies was evaluated using the Cochrane Q test and I2 statistics. Funnel plots were used for the assessment of publication bias. Results: Seven prospective studies including 574 parturients (including 396 pre-eclamptics) were selected. POCUS included lung, optic nerve, cardiac and thoracic US. In two studies, the ECS and LUS scores pre-delivery were higher in pre-eclamptics. Two studies found a mean ONSD of 5–5.84 mm before delivery. MA revealed a significantly lower mean ECS score at post-delivery than pre-delivery, and the summary prevalence of B-pattern and pleural effusion among SPE parturients was found to be 0.28 (0.03–0.84) and 0.1 (0–0.2), respectively. A good correlation was observed between B-line patterns and diastolic dysfunction (increased E/e' ratio), LUS score and thoracic fluid content, ONSD and ECS in individual studies. Conclusion: POCUS parameters can be useful as early markers of fluid status and serve as useful tools in the precise clinical management of pre-eclampsia.
Details
- Language :
- English
- ISSN :
- 00195049 and 09762817
- Volume :
- 65
- Issue :
- 10
- Database :
- Directory of Open Access Journals
- Journal :
- Indian Journal of Anaesthesia
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.9e06bb38404e3ab1ba2c4899c4f06d
- Document Type :
- article
- Full Text :
- https://doi.org/10.4103/ija.ija_820_21