- AIM: To investigate the safety and efficacy of using a one-step viscoelastic agent technique for posterior chamber phakic implantable collamer lens with a central hole (ICL V4c) implantation for myopia correction. METHODS: The one-step viscoelastic agent technique for ICL V4c implantation was used in 100 eyes of 52 patients. Refractive outcomes, intraocular pressure (IOP), corneal endothelial cell, and corneal densitometry values were evaluated at 1d, 1wk, 1 and 3mo postoperatively. RESULTS: All the surgeries were uneventful. No corrected distance visual acuity was lost after 3mo. IOP was 16.12±3.18 mm Hg before surgery, and 14.74±3.08 mm Hg at 1d and 14.50±2.56 mm Hg at 3mo after surgery (P0.05). The corneal densitometry values of the central 2 mm and 2 to 6 mm areas showed similar regularities. After surgery, the values significantly increased at 1d, then decreased to the preoperative values at 1wk, and then continued to decrease at 3mo (P