Back to Search Start Over

Evaluation of KRAS, NRAS and BRAF hotspot mutations detection for patients with metastatic colorectal cancer using direct DNA pipetting in a fully-automated platform and Next-Generation Sequencing for laboratory workflow optimisation.

Authors :
Pauline Gilson
Claire Franczak
Ludovic Dubouis
Marie Husson
Marie Rouyer
Jessica Demange
Marie Perceau
Agnès Leroux
Jean-Louis Merlin
Alexandre Harlé
Source :
PLoS ONE, Vol 14, Iss 7, p e0219204 (2019)
Publication Year :
2019
Publisher :
Public Library of Science (PLoS), 2019.

Abstract

BACKGROUND:Assessment of KRAS, NRAS (RAS) and BRAF mutations is a standard in the management of patients with metastatic colorectal cancer (mCRC). Mutations could be assessed using next-generation sequencing (NGS) or real-time PCR-based assays. Times to results are 1 to 2 weeks for NGS and 1 to 3 days for real-time PCR-based assays. Using NGS can delay first-line treatment commencement and using PCR-based assays is limited by the number of possible analysed targets. The Idylla system is a real-time PCR cartridge-based assay, able to analyse hotspots mutations using one section of FFPE tumour tissue sample. To combine short delays and analysis of a large gene-panel, we propose here a laboratory workflow combining the Idylla system and NGS and compatible with FFPE samples with low tissue quantity. In this study we evaluated and validated the Idylla system for the analysis of RAS and BRAF mutations by pipetting directly DNA in the cartridge instead of FFPE section as recommended by the manufacturer. MATERIALS AND METHODS:DNA extracted from 29 FFPE samples from mCRC patients with NGS-characterized RAS and BRAF mutations were tested with the Idylla KRAS and the Idylla NRAS-BRAF mutation tests to assess sensitivity, specificity, reproducibility and limit of detection of each test. RESULTS:A 100% concordance was found between NGS and Idylla results for the determination of KRAS (12/12), NRAS (12/12) and BRAF (11/11) mutations with a sensitivity and a specificity of 100%. The system showed a good reproducibility with CV inferior to 3%. LOD was reached with 2.5 ng of DNA for KRAS and NRAS mutations and 5 ng of DNA for BRAF mutations. CONCLUSIONS:The analysis of RAS and BRAF mutations using DNA pipetted directly in the cartridge of the Idylla system showed a good sensitivity, specificity, reproducibility and LOD, and can be integrated in a laboratory workflow for samples with few tissue without compromising a further complete tumour characterization using NGS.

Subjects

Subjects :
Medicine
Science

Details

Language :
English
ISSN :
19326203
Volume :
14
Issue :
7
Database :
Directory of Open Access Journals
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
edsdoj.98f830e68b924efbb83d3cc3c7fd1d74
Document Type :
article
Full Text :
https://doi.org/10.1371/journal.pone.0219204