Back to Search Start Over

A Zero-Cross Detection Algorithm for Cavity-Length Interrogation of Fiber-Optic Fabry–Perot Sensors

Authors :
Zhibo Ma
Zechen Song
Xirui Huang
Tongxin Guo
Weizheng Yuan
Haibin Chen
Tianyang Zhang
Wei Wang
Source :
Sensors, Vol 19, Iss 18, p 3868 (2019)
Publication Year :
2019
Publisher :
MDPI AG, 2019.

Abstract

A zero-cross detection algorithm was proposed for the cavity-length interrogation of fiber-optic Fabry−Perot (FP) sensors. The method can avoid the inaccuracy of peak determination in the conventional peak-to-peak method for the cavity-length interrogation of fiber-optic FP sensors caused by the slow variation of the spectral power density in peak neighboring regions. Both simulations and experiments were carried out to investigate the feasibility and performance of the zero-cross detection algorithm. Fiber-optic FP sensors with cavity lengths in the range of 150−1000 μm were successfully interrogated with a maximum error of 0.083 μm.