Abstract

MCNPX, Geant4 and FLUKA codes are employed to compute mass attenuation coefficients (μ/ρ) for 20Bi2O3-(80-x)B2O3-xPbO (x = 0, 20, 30, 40 and 60 mol%) glasses at 20, 30, 40 and 60 KeV, 133Ba (81, 161, 223, 276, 303, 356 and 384 keV), 57Co (122 and 136 KeV), 22Na (511 and 1275 keV), 137Cs (662 keV), 54Mn (835 keV), 60Co (1173 and 1333 keV) and 42K (1524 keV) photon peaks where 20, 30, 40 and 60 KeV energies are utilized for Mammography, Dental, General and Computed tomography (CT) scanning accordingly, in this study. All simulated μ/ρ outcomes accuracy was verified by WinXCOM and Phy-X/PSD programs’ μ/ρ findings and we noticed a satisfactory agreement among them. From μ/ρ and linear attenuation coefficient (μ) values effective atomic number (Zeff), effective electron density (Neff), half-value layer (HVL), tenth-value layer (TVL) and mean free path (MFP) have been determined. 20Bi2O3-20B2O3-60PbO (mol%) glass HVL and MFP have been compared with some commercial glasses, alloys, polymers, concretes and lead and ceramics corresponding values. Later equivalent atomic numbers (Zeq) and applying geometric progression (G–P) fitting method at 1 – 40 mfp penetration depths (PDs) at 0.015–15 MeV energy range exposure buildup factors (EBFs) and energy absorption buildup factors (EABFs) were estimated. At all selected twenty energies derived radiation protection efficiency (RPE) results confirmed studied samples’ excellent efficacy for low energy photons absorption. Moreover, applying SRIM codes mass stopping powers (MSPs) and projected ranges (PRs) for protons and α-particles and utilizing ESTAR database electron MSPs and continuous slowing down approximation (CSDA) range for electrons were determined at kinetic energy (KE) range of 0.015–15 MeV. Further fast neutron removal cross-sections (ΣR), for 0.0253 eV energy neutrons coherent and incoherent scattering cross-sections (σcs and σics), absorption cross-section (σA) and total cross-section (σT) quantities were evaluated. Derived ΣR was changed at 0.1166–0.123 cm−1 range depending on PbO addition in chosen samples. 20Bi2O3-80B2O3 (mol%) glass has larger σT (23.094 cm−1) in all studied samples for thermal neutron absorption while 20Bi2O3-20B2O3-60PbO (mol%) sample shows superior attenuation factors for photons and fast neutrons signifying included PbO positive effect.

Details

Language :
English
ISSN :
22113797
Volume :
23
Issue :
104030-
Database :
Directory of Open Access Journals
Journal :
Results in Physics
Publication Type :
Academic Journal
Accession number :
edsdoj.97753d738c524612ae1b5a26a63ca8f4
Document Type :
article
Full Text :
https://doi.org/10.1016/j.rinp.2021.104030