Back to Search Start Over

Five-Year Follow-Up of a Slowly Resorbable Biosynthetic P4HB Mesh (Phasix) in VHWG Grade 3 Incisional Hernia Repair

Authors :
L. M. Van den Dop, MD
M. M. J. Van Rooijen, MD, PhD
T. Tollens, MD
L. N. Jørgensen, MD, PhD
T. S. De Vries-Reilingh, MD, PhD
G. Piessen, MD, PhD
F. Köckerling, MD, PhD
M. Miserez, MD, PhD
M. Dean, MD
F. Berrevoet, MD, PhD
B. Dousset, MD, PhD
H. L. Van Westreenen, MD, PhD
F. Gossetti, MD, PhD
G. W. M. Tetteroo, MD, PhD
A. Koch, MD, PhD
M. F. Boomsma, MD, PhD
J. F. Lange, MD, PhD
J. Jeekel, MD, PhD
Source :
Annals of Surgery Open, Vol 4, Iss 4, p e366 (2023)
Publication Year :
2023
Publisher :
Wolters Kluwer Health, 2023.

Abstract

Objective:. To assess the 5-year recurrence rate of incisional hernia repair in Ventral Hernia Working Group (VHWG) 3 hernia with a slowly resorbable mesh. Summary Background Data:. Incisional hernia recurs frequently after initial repair. In potentially contaminated hernia, recurrences rise to 40%. Recently, the biosynthetic Phasix mesh has been developed that is resorbed in 12–18 months. Resorbable meshes might be a solution for incisional hernia repair to decrease short- and long-term (mesh) complications. However, long-term outcomes after resorption are scarce. Methods:. Patients with VHWG grade 3 incisional midline hernia, who participated in the Phasix trial (Clinilcaltrials.gov: NCT02720042) were included by means of physical examination and computed tomography (CT). Primary outcome was hernia recurrence; secondary outcomes comprised of long-term mesh complications, reoperations, and abdominal wall pain [visual analogue score (VAS): 0–10]. Results:. In total, 61/84 (72.6%) patients were seen. Median follow-up time was 60.0 [interquartile range (IQR): 55–64] months. CT scan was made in 39 patients (68.4%). A recurrence rate of 15.9% (95% confidence interval: 6.9–24.8) was calculated after 5 years. Four new recurrences (6.6%) were found between 2 and 5 years. Two were asymptomatic. In total, 13/84 recurrences were found. No long-term mesh complications and/or interventions occurred. VAS scores were 0 (IQR: 0–2). Conclusions:. Hernia repair with Phasix mesh in high-risk patients (VHWG 3, body mass index >28) demonstrated a recurrence rate of 15.9%, low pain scores, no mesh-related complications or reoperations for chronic pain between the 2- and 5-year follow-up. Four new recurrences occurred, 2 were asymptomatic. The poly-4-hydroxybutyrate mesh is a safe mesh for hernia repair in VHWG 3 patients, which avoids long-term mesh complications like pain and mesh infection.

Subjects

Subjects :
Surgery
RD1-811

Details

Language :
English
ISSN :
26913593 and 00000000
Volume :
4
Issue :
4
Database :
Directory of Open Access Journals
Journal :
Annals of Surgery Open
Publication Type :
Academic Journal
Accession number :
edsdoj.9721d6902cc242f380561118d5651c8e
Document Type :
article
Full Text :
https://doi.org/10.1097/AS9.0000000000000366