Back to Search Start Over

Evaluation of COVID-19 rapid antigen test against polymerase chain reaction test in immunocompromised patients.

Authors :
Ali Sabateen
Dana Sadaqa
Taleen Nino
Ghayd Zaghal
George Qumsieh
Reena Fakhori
Hammam Rjoub
Tahreer Taha
Rami Zghari
Sari Abu Hanieh
Duaa Al-Basha
Marwan Qabaja
Hamza Alsaid
Musa Y Hindiyeh
Source :
PLoS ONE, Vol 19, Iss 8, p e0306396 (2024)
Publication Year :
2024
Publisher :
Public Library of Science (PLoS), 2024.

Abstract

On the 11th of March 2020, the world faced a new global pandemic, COVID-19 which is a disease caused by the novel coronavirus, it had multiple devastating outcomes on multiple sectors along with significant rates of mortality. These challenges encouraged the development of multiple testing methods, as well as anti-viral medications such as Molnupiravir, as well as evaluating the efficacy of available medications against it, like; Azithromycin, Ritonavir and Hydroxychloroquine. Vaccination against COVID-19 forged into a significant challenge, few months ensuing the first case of SARS-CoV-2, which was diagnosed in December 2019, in Wuhan-China, thus, multiple vaccines were approved for use around the world to combat this pandemic. Our study includes a sample of 556 oncology patients at Augusta Victoria Hospital in Jerusalem, all patients were tested using Panbio rapid antigen test and Allplex PCR Assay. The main objective was to study the sensitivity and specificity of Rapid antigen test, which contributes to a faster isolation call and management of infected patients, thus decreasing the risk on spread to other patients and health care. Patients were categorized based on two factors: Ct range and age group and studying their possible effect on false-negative results. Patients with Ct value less than 20, had the highest detection rate which is consistent with other studies in the literature. The sensitivity and specificity of Panbio Rapid Antigen testing were of 69.9% and 100%, respectively. A correlation between age group and false negative results could not be made, but a correlation between Ct value and false negative result was noticed, Ct value was directly related to false negative results. P-value of 0.007 indicated that results were statistically significant where PCR test is considered more sensitive compared to rapid antigen test.

Subjects

Subjects :
Medicine
Science

Details

Language :
English
ISSN :
19326203
Volume :
19
Issue :
8
Database :
Directory of Open Access Journals
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
edsdoj.94d55a693ddb4687af3fd2ca00be91d3
Document Type :
article
Full Text :
https://doi.org/10.1371/journal.pone.0306396