Back to Search Start Over

Impact of Tracer Dose Reduction in [18 F]-Labelled Fluorodeoxyglucose-Positron Emission Tomography ([18 F]-FDG)-PET) on Texture Features and Histogram Indices: A Study in Homogeneous Tissues of Phantom and Patient

Authors :
Jonas Vogel
Ferdinand Seith
Arne Estler
Konstantin Nikolaou
Holger Schmidt
Christian la Fougère
Thomas Küstner
Source :
Tomography, Vol 9, Iss 5, Pp 1799-1810 (2023)
Publication Year :
2023
Publisher :
MDPI AG, 2023.

Abstract

Background: Histogram indices (HIs) and texture features (TFs) are considered to play an important role in future oncologic PET-imaging and it is unknown how these indices are affected by changes of tracer doses. A randomized undersampling of PET list mode data enables a simulation of tracer dose reduction. We performed a phantom study to compare HIs/TFs of simulated and measured tracer dose reductions and evaluated changes of HIs/TFs in the liver of patients with PETs from simulated reduced tracer doses. Overall, 42 HIs/TFs were evaluated in a NEMA phantom at measured and simulated doses (stepwise reduction of [18 F] from 100% to 25% of the measured dose). [18 F]-FDG-PET datasets of 15 patients were simulated from 3.0 down to 0.5 MBq/kgBW in intervals of 0.25 MBq/kgBW. HIs/TFs were calculated from two VOIs placed in physiological tissue of the right and left liver lobe and linear correlations and coefficients of variation analysis were performed. Results: All 42 TFs did not differ significantly in measured and simulated doses (p > 0.05). Also, 40 TFs showed the same behaviour over dose reduction regarding differences in the same group (measured or simulated), and for 26 TFs a linear behaviour over dose reduction for measured and simulated doses could be validated. Out of these, 13 TFs could be identified, which showed a linear change in TF value in both the NEMA phantom and patient data and therefore should maintain the same informative value when transferred in a dose reduction setting. Out of this Homogeneity 2, Entropy and Zone size non-uniformity are of special interest because they have been described as preferentially considerable for tumour heterogeneity characterization. Conclusions: We could show that there was no significant difference of measured and simulated HIs/TFs in the phantom study and most TFs reveal a linear behaviour over dose reduction, when tested in homogeneous tissue. This indicates that texture analysis in PET might be robust to dose modulations.

Details

Language :
English
ISSN :
2379139X and 23791381
Volume :
9
Issue :
5
Database :
Directory of Open Access Journals
Journal :
Tomography
Publication Type :
Academic Journal
Accession number :
edsdoj.93af23a8c7421a8e6157ba0ed0a658
Document Type :
article
Full Text :
https://doi.org/10.3390/tomography9050143