Back to Search Start Over

A highly sensitive liquid chromatography electrospray ionization mass spectrometry method for quantification of TMA, TMAO and creatinine in mouse urine

Authors :
Sunil Veeravalli
Kersti Karu
Ian R. Phillips
Elizabeth A. Shephard
Source :
MethodsX, Vol 4, Iss C, Pp 310-319 (2017)
Publication Year :
2017
Publisher :
Elsevier, 2017.

Abstract

Our method describes the quantification in mouse urine of trimethylamine (TMA), trimethylamine N-oxide (TMAO) and creatinine. The method combines derivatization of TMA, with ethyl bromoacetate, and LC chromatographic separation on an ACE C18 column. The effluent was continuously electrosprayed into the linear ion trap mass spectrometer (LTQ), which operated in selective ion monitoring (SIM) modes set for targeted analytes and their internal standards (IS). All validation parameters were within acceptable ranges of analytical method validation guidelines. Intra- and inter-day assay precision and accuracy coefficients of variation were