Back to Search Start Over

3-Dimensional Modeling Guided Transcatheter Repair of Dehisced Pulmonary Venous Baffle With Gore ASD Device

Authors :
Analise Sulentic, BS
Mudit Gupta, MD, PhD
Silvani Amin, BA
Yan Wang, RDDS
Danish Vaiyani, MD
Patricia Sabin, MS
Sara L. Partington, MD
Matthew J. Gillespie, MD
Matthew A. Jolley, MD
Source :
JACC: Case Reports, Vol 21, Iss , Pp 101968- (2023)
Publication Year :
2023
Publisher :
Elsevier, 2023.

Abstract

A 38-year-old woman with sinus venosus atrial septal defect and partial anomalous return of the right upper pulmonary vein underwent a Warden procedure but experienced a large residual defect after patch dehiscence. Image-derived 3D modeling informed novel device closure with a Gore Cardioform atrial septal occluder. (Level of Difficulty: Advanced.)

Details

Language :
English
ISSN :
26660849
Volume :
21
Issue :
101968-
Database :
Directory of Open Access Journals
Journal :
JACC: Case Reports
Publication Type :
Academic Journal
Accession number :
edsdoj.935336fd21f94f45b6a8638c33b4c41a
Document Type :
article
Full Text :
https://doi.org/10.1016/j.jaccas.2023.101968