Back to Search Start Over

Comparison between 68Ga-PSMA-11 PET/CT and multiparametric magnetic resonance imaging in patients with biochemically recurrent prostate cancer following robot-assisted radical prostatectomy

Authors :
Jing-Ren Tseng
Kai-Jie Yu
Feng-Yuan Liu
Lan-Yan Yang
Ji-Hong Hong
Tzu-Chen Yen
See-Tong Pang
Li-Jen Wang
Source :
Journal of the Formosan Medical Association, Vol 120, Iss 1, Pp 688-696 (2021)
Publication Year :
2021
Publisher :
Elsevier, 2021.

Abstract

Background/Purpose: We sought to compare the diagnostic performances of 68Ga-PSMA-11 PET/CT and prostate/whole-abdomen multiparametric magnetic resonance imaging (PWAmpMRI) in Taiwanese patients with biochemically recurrent prostate cancer following robot-assisted radical prostatectomy. Methods: Between June 2017 and December 2018, we prospectively enrolled 34 patients. Upon review of all available clinical and imaging data, a best valuable comparator (BVC) was defined on an individual basis in the light of a consensus reached by a multidisciplinary tumor board. Diagnostic positivity was investigated in relation to the different lesion types. Results: On a patient-based analysis, 68Ga-PSMA-11 PET/CT and PWAmpMRI showed a moderate agreement (kappa coefficient = 0.62). 68Ga-PSMA-11 PET/CT identified local recurrences, regional, and non-regional lymph node metastases, and bone metastases in 15, 10, 1, and 5 patients, respectively. Conversely, PWAmpMRI detected these lesions in 26, 8, 1, and 4 patients, respectively. When the BVC was used as reference standard, the positive diagnostic rates for local recurrences, regional lymph node metastases, non-regional lymph node metastases, and bone metastases were 57.7%, 90.9%, 100%, and 100%, respectively for 68Ga-PSMA-11 PET/CT, and 100%, 72.7%, 100%, and 80% for PWAmpMRI, respectively. The use of both PWAmpMRI and 68Ga-PSMA-11 PET/CT showed a complete diagnostic yield for detecting both local recurrence and systemic failure when PSA levels reached 0.5 ng/mL. Conclusion: Due to urine radioactivity, 68Ga-PSMA-11 PET/CT performs less than PWAmpMRI on local recurrences. However, it can have a complementary diagnostic role in the detection of lymph node metastases and in identifying non-axial bone metastases beyond the PWAmpMRI scanning field.

Details

Language :
English
ISSN :
09296646
Volume :
120
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Journal of the Formosan Medical Association
Publication Type :
Academic Journal
Accession number :
edsdoj.927c808bd39d4637a520827fe49a0707
Document Type :
article
Full Text :
https://doi.org/10.1016/j.jfma.2020.07.029