Back to Search Start Over

CLYC as a neutron detector in low background conditions

Authors :
J. Plaza
V. Bécares
D. Cano-Ott
C. Gómez
T. Martínez
E. Mendoza
A. Pérez de Rada
V. Pesudo
J. C. Sáez-Vergara
R. Santorelli
D. Villamarín
A. Ianni
C. Peña
J. Balibrea-Correa
A. Boeltzig
G. Imbriani
Source :
European Physical Journal C: Particles and Fields, Vol 83, Iss 11, Pp 1-10 (2023)
Publication Year :
2023
Publisher :
SpringerOpen, 2023.

Abstract

Abstract We report on the thermal neutron flux measurements carried out at the Laboratorio Subterráneo de Canfranc (LSC) with two commercial $$2^{\prime \prime } \times 2^{\prime \prime }$$ 2 ″ × 2 ″ CLYC detectors. The measurements were performed as part of an experimental campaign at LSC with $$^{3}$$ 3 He detectors, for establishing the sensitivity limits and use of CLYCs in low background conditions. A careful characterization of the intrinsic $$\alpha $$ α and $$\gamma $$ γ -ray background in the detectors was required and done with dedicated measurements. It was found that the $$\alpha $$ α activities in the two CLYC crystals differ by a factor of three, and the use of Monte Carlo simulations and a Bayesian unfolding method allowed us to determine the specific $$\alpha $$ α activities from the $$^{238}$$ 238 U and $$^{232}$$ 232 Th decay chains. The simulations and unfolding also revealed that the $$\gamma $$ γ -ray background registered in the detectors is dominated by the intrinsic activity of the components of the detector such as the aluminum housing and photo-multiplier and that the activity within the crystal is low in comparison. The data from the neutron flux measurements with the two detectors were analyzed with different methodologies: one based on an innovative $$\alpha $$ α /neutron pulse shape discrimination method and one based on the subtraction of the intrinsic $$\alpha $$ α background that masks the neutron signals in the region of interest. The neutron sensitivity of the CLYCs was calculated by Monte Carlo simulations with MCNP6 and GEANT4. The resulting thermal neutron fluxes are in good agreement with complementary flux measurement performed with $$^{3}$$ 3 He detectors, but close to the detection limit imposed by the intrinsic $$\alpha $$ α activity.

Details

Language :
English
ISSN :
14346052
Volume :
83
Issue :
11
Database :
Directory of Open Access Journals
Journal :
European Physical Journal C: Particles and Fields
Publication Type :
Academic Journal
Accession number :
edsdoj.9139b2234cd0431b88eaadb240558738
Document Type :
article
Full Text :
https://doi.org/10.1140/epjc/s10052-023-12221-3