Zero‐fluoroscopy catheter ablation of premature ventricular contractions at left coronary cusp near left main coronary artery

Authors :
Amato Santoro
Claudia Baiocchi
Flavio D’Ascenzi
Sergio Mondillo
Serafina Valente
Source :
Clinical Case Reports, Vol 8, Iss 10, Pp 1952-1956 (2020)
Publication Year :
2020
Publisher :
Wiley, 2020.

Abstract

Abstract The left coronary cusp is the commonest site of origin for coronary cusp PVC. Catheter ablation without fluoroscopy is highly effective, feasible, and safe but it could be related to risks because of proximity to the coronary arteries. The use of ICE integration allowed an improvement in the safety and efficiency of these procedures.