Back to Search Start Over

The Validity and Absolute Reliability of Lower Extremity Angle Values on Full-Leg Standing Radiographs Using the TraumaMeter Software

Authors :
Vicente J. León-Muñoz
José Hurtado-Avilés
Joaquín Moya-Angeler
Gregorio Valero-Cifuentes
Irene Hernández-Martínez
Alejandro J. Castillo-Botero
Erica Lante
Rocío Martínez-Sola
Fernando Santonja-Renedo
Francisco J. Sánchez-Martínez
Vicente Ferrer-López
Emilio José Salmerón-Martínez
Fernando Santonja-Medina
Source :
Applied Sciences, Vol 14, Iss 2, p 565 (2024)
Publication Year :
2024
Publisher :
MDPI AG, 2024.

Abstract

To establish classifications and to obtain pre- and post-operative information on patient-specific alignments, it is necessary to measure different angular values accurately and precisely, mainly on weight-bearing, full-length anteroposterior X-rays of the lower limbs (LLRs). This study evaluated angular measurements’ validity and absolute reliability on LLRs with a self-developed, computer-aided measurement system (TraumaMeter v.873). Eight independent observers measured the preoperative mechanical hip-knee-ankle (mHKA) angle of 52 lower extremities (26 cases) in a blinded fashion on three occasions separated by two weeks. We obtained an intra-observer mean bias error (MBE) of 0.40°, a standard deviation (SD) of 0.11°, and a 95% confidence interval (CI) of 0.37°–0.43°. We also obtained an inter-observer MBE of 0.49°, an SD of 0.15°, and a 95% C of 0.45°–0.53°. The intra-observer MBE for the measurement pair between the second and the first measurement round (T2T1) was 0.43°, the SD was 0.13°, and the 95% CI was 0.39°–0.47°; the MBE between the third and the second round (T3T2) was 0.37°, with an SD of 0.10° and a 95% CI of 0.34°–0.40°; and the MBE between the third and the first round (T3T1) was 0.40°, with an SD of 0.10° and a 95% CI of 0.37°–0.43°. The interobserver MBE for the first round of measurements was 0.52°, with an SD of 0.16° and a 95% CI of 0.48°–0.56°; the MBE for the second round was 0.50°, with an SD of 0.15° and a 95% CI of 0.46°–0.54°; and the MBE for the third round was 0.46°, with an SD of 0.14° and a 95% CI of 0.42°–0.50°. There were no statistically significant differences in the inter-observer errors for the three tests. In the case of the intra-observer analysis, there were differences between T2T1 and between T3T2, but these differences were minimal, with no overlaps in the lower or upper values, respectively, of the confidence intervals. These results led us to conclude that the TraumaMeter v.873 software extension for measuring lower-limb angles in LLRs is an accurate tool with low intra- and inter-observer variability.

Details

Language :
English
ISSN :
20763417
Volume :
14
Issue :
2
Database :
Directory of Open Access Journals
Journal :
Applied Sciences
Publication Type :
Academic Journal
Accession number :
edsdoj.8fa5053b1e904f579eddf45fe3eb5288
Document Type :
article
Full Text :
https://doi.org/10.3390/app14020565