Back to Search Start Over

A randomised controlled trial and cost-effectiveness analysis of high-frequency oscillatory ventilation against conventional artificial ventilation for adults with acute respiratory distress syndrome. The OSCAR (OSCillation in ARDS) study

Authors :
Ranjit Lall
Patrick Hamilton
Duncan Young
Claire Hulme
Peter Hall
Sanjoy Shah
Iain MacKenzie
William Tunnicliffe
Kathy Rowan
Brian Cuthbertson
Chris McCabe
Sallie Lamb
on behalf of the OSCAR collaborators
Source :
Health Technology Assessment, Vol 19, Iss 23 (2015)
Publication Year :
2015
Publisher :
NIHR Journals Library, 2015.

Abstract

Background: Patients with the acute respiratory distress syndrome (ARDS) require artificial ventilation but this treatment may produce secondary lung damage. High-frequency oscillatory ventilation (HFOV) may reduce this damage. Objectives: To determine the clinical benefit and cost-effectiveness of HFOV in patients with ARDS compared with standard mechanical ventilation. Design: A parallel, randomised, unblinded clinical trial. Setting: UK intensive care units. Participants: Mechanically ventilated patients with a partial pressure of oxygen in arterial blood/fractional concentration of inspired oxygen (P : F) ratio of 26.7 kPa (200 mmHg) or less and an expected duration of ventilation of at least 2 days at recruitment. Interventions: Treatment arm HFOV using a Novalung R100® ventilator (Metran Co. Ltd, Saitama, Japan) ventilator until the start of weaning. Control arm Conventional mechanical ventilation using the devices available in the participating centres. Main outcome measures: The primary clinical outcome was all-cause mortality at 30 days after randomisation. The primary health economic outcome was the cost per quality-adjusted life-year (QALY) gained. Results: One hundred and sixty-six of 398 patients (41.7%) randomised to the HFOV group and 163 of 397 patients (41.1%) randomised to the conventional mechanical ventilation group died within 30 days of randomisation (p = 0.85), for an absolute difference of 0.6% [95% confidence interval (CI) −6.1% to 7.5%]. After adjustment for study centre, sex, Acute Physiology and Chronic Health Evaluation II score, and the initial P : F ratio, the odds ratio for survival in the conventional ventilation group was 1.03 (95% CI 0.75 to 1.40; p = 0.87 logistic regression). Survival analysis showed no difference in the probability of survival up to 12 months after randomisation. The average QALY at 1 year in the HFOV group was 0.302 compared to 0.246. This gives an incremental cost-effectiveness ratio (ICER) for the cost to society per QALY of £88,790 and an ICER for the cost to the NHS per QALY of £78,260. Conclusions: The use of HFOV had no effect on 30-day mortality in adult patients undergoing mechanical ventilation for ARDS and no economic advantage. We suggest that further research into avoiding ventilator-induced lung injury should concentrate on ventilatory strategies other than HFOV. Trial registration: Current Controlled Trials ISRCTN10416500. Funding: This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 19, No. 23. See the NIHR Journals Library website for further project information.

Details

Language :
English
ISSN :
13665278 and 20464924
Volume :
19
Issue :
23
Database :
Directory of Open Access Journals
Journal :
Health Technology Assessment
Publication Type :
Academic Journal
Accession number :
edsdoj.8cba0241774d40e1a59a717088cb957e
Document Type :
article
Full Text :
https://doi.org/10.3310/hta19230