Back to Search Start Over

Added Value of a New Strain Elastography Technique in Conventional Ultrasound for the Diagnosis of Breast Masses: A Prospective Multicenter Study

Authors :
Qi Wei
Yu-Jing Yan
Ge-Ge Wu
Xi-Rong Ye
Fan Jiang
Jie Liu
Gang Wang
Yi Wang
Yu Wang
Zhi-Ping Pan
Jin-Hua Hu
Juan Song
Christoph F. Dietrich
Xin-Wu Cui
Source :
Frontiers in Oncology, Vol 11 (2021)
Publication Year :
2021
Publisher :
Frontiers Media S.A., 2021.

Abstract

ObjectiveThis study aimed to explore the value of elasticity score (ES) and strain ratio (SR) combined with conventional ultrasound in distinguishing benign and malignant breast masses and reducing biopsy of BI-RADS (Breast Imaging Reporting and Data System) 4a lesions.MethodsThis prospective, multicenter study included 910 patients from nine different hospitals. The acquisition and analysis of conventional ultrasound and strain elastography (SE) were obtained by radiologists with more than 5 years of experience in breast ultrasound imaging. The diagnostic sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under curve (AUC) of conventional ultrasound alone and combined tests with ES and/or SR were calculated and compared.ResultsThe optimal cutoff value of SR for differentiating benign from malignant masses was 2.27, with a sensitivity of 60.2% and a specificity of 84.8%. When combined with ES and SR, the AUC of the new BI-RADS classification increased from 0.733 to 0.824 (p < 0.001); the specificity increased from 48.1% to 68.5% (p < 0.001) without a decrease in the sensitivity (98.5% vs. 96.4%, p = 0.065); and the PPV increased from 52.2% to 63.7% (p < 0.001) without a loss in the NPV (98.2% vs. 97.1%, p = 0.327). All three combinations of conventional ultrasound, ES, and SR could reduce the biopsy rate of category 4a lesions without reducing the malignant rate of biopsy (from 100% to 68.3%, 34.9%, and 50.4%, respectively, all p < 0.001).ConclusionsSE can be used as a useful and non-invasive additional method to improve the diagnostic performance of conventional ultrasound by increasing AUC and specificity and reducing the unnecessary biopsy of BI-RADS 4a lesions.

Details

Language :
English
ISSN :
2234943X
Volume :
11
Database :
Directory of Open Access Journals
Journal :
Frontiers in Oncology
Publication Type :
Academic Journal
Accession number :
edsdoj.8c2cf83cd3ad4c9096e7f412b39902bd
Document Type :
article
Full Text :
https://doi.org/10.3389/fonc.2021.779612