Back to Search
Start Over
Estimating point and interval frequency of antigen-specific CD4+ T cells based on short in vitro expansion and improved poisson distribution analysis.
- Source :
- PLoS ONE, Vol 7, Iss 8, p e42340 (2012)
- Publication Year :
- 2012
- Publisher :
- Public Library of Science (PLoS), 2012.
-
Abstract
- BACKGROUND: Knowledge of antigen-specific CD4(+) T cells frequencies is pivotal to the choice of the antigen to be used in anti-viral and anti-tumor vaccination procedures and for monitoring of immune responses. Methods that employ small cell numbers from patient samples, are easy to perform and do not require complex techniques/instrumentations and therefore standardization are desirable. METHODOLOGY/PRINCIPAL FINDINGS: Purified blood CD4(+) T cells from healthy donors were cultured with autologous antigen presenting cells in several replicate wells in equal numbers in the absence (un-stimulated wells) or in the presence of synthetic peptides corresponding to viral antigens promiscuous HLA-DR epitopes (antigen-stimulated wells). At day 7 of culture low dose IL-2 was added and at day 14 IFN-γ and IL-5 release in the supernatant was measured. A statistical analysis approach, based on Poisson distribution, was then implemented to calculate the frequency of viral-specific CD4(+) T cells. We first determined a patient-specific exceptionality threshold of cytokine release in the un-stimulated wells and then, based on this threshold, we counted the inactive/active wells within the antigen-stimulated wells. This number, along with the number of cells per well, allowed the point and interval estimates of frequencies. A ready-to-use Excel worksheet template with automatic calculations for frequencies estimate was developed and is provided as a supplemental file (Table S9). CONCLUSIONS/SIGNIFICANCE: We report a simple experimental procedure combining short term in vitro cell culture with statistical analysis to calculate the frequency of antigen-specific CD4(+) T cells. The detailed experimental procedure along with the Excel applicative are a valuable tool for monitoring immune responses in the clinical practice.
Details
- Language :
- English
- ISSN :
- 19326203
- Volume :
- 7
- Issue :
- 8
- Database :
- Directory of Open Access Journals
- Journal :
- PLoS ONE
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.8ab4cce48504d269ed37fdc55c2ed51
- Document Type :
- article
- Full Text :
- https://doi.org/10.1371/journal.pone.0042340