Back to Search
Start Over
Vesicant infusates are not associated with ultrasound-guided peripheral intravenous catheter failure: A secondary analysis of existing data.
- Source :
- PLoS ONE, Vol 17, Iss 1, p e0262793 (2022)
- Publication Year :
- 2022
- Publisher :
- Public Library of Science (PLoS), 2022.
-
Abstract
- BackgroundIntravenous vesicants are commonly infused via peripheral intravenous catheters (PIVC) despite guidelines recommending administration via central route. The impact of these medications on PIVC failure is unclear. We aimed to assess dose-related impact of these caustic medications on ultrasound-guided (US) PIVC survivorship.MethodsWe performed a secondary analysis of a randomized control trial that compared survival of two catheters: a standard long (SL) and an ultra-long (UL) US PIVC. This study involved reviewing and recording all vesicants infusions through the PIVCs. Type and number of vesicants doses were extracted and characterized as one, two or multiple. The most commonly used vesicants were individually categorized for further analysis. The primary outcome was PIVC failure accounting for use and timing of vesicant infusates.ResultsBetween October 2018 and March 2019, 257 subjects were randomized with 131 in the UL group and 126 in the SL group. Vesicants were infused in 96 (37.4%) out of 257 study participants. In multivariable time-dependent extended Cox regression analysis, there was no significant increased risk of failure due to vesicant use [adjusted hazard ratio, aHR 1.71 (95% CI 0.76-1.81) p = 0.477]. The number of vesicant doses was not significantly associated with the increased risk of PIVC failure [(1 vs 0) aHR 1.20 (95% CI 0.71-2.02) p = 0.500], [(2 vs 0) aHR 1.51 (95% CI 0.67-3.43) p = 0.320] and [(≥ 3 vs 0) aHR 0.98 (95% CI 0.50-1.92) p = 0.952].ConclusionVesicant usage did not significantly increase the risk of PIVC failure even when multiple doses were needed in this investigation. Ultrasound-guided PIVCs represent a pragmatic option when vesicant therapy is anticipated. Nevertheless, it is notable that overall PIVC failure rates remain high and other safety events related to vesicant use should be considered when clinicians make vascular access decisions for patients.
Details
- Language :
- English
- ISSN :
- 19326203
- Volume :
- 17
- Issue :
- 1
- Database :
- Directory of Open Access Journals
- Journal :
- PLoS ONE
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.8a75ed71707d4be7bc5a34dbef60d2ff
- Document Type :
- article
- Full Text :
- https://doi.org/10.1371/journal.pone.0262793