Back to Search Start Over

Validation of the SCALE/Polaris−PARCS Code Procedure with the ENDF/B-VII.1 AMPX 56-Group Library: Pressurized Water Reactor

Authors :
Kang Seog Kim
Byoung-Kyu Jeon
Andrew Ward
Ugur Mertyurek
Matthew Jessee
William Wieselquist
Source :
Journal of Nuclear Engineering, Vol 5, Iss 3, Pp 246-259 (2024)
Publication Year :
2024
Publisher :
MDPI AG, 2024.

Abstract

This study was conducted to validate the SCALE/Polaris v6.3.0–PARCS v3.4.2 code procedure with the Evaluated Nuclear Data File (ENDF)/B-VII.1 AMPX 56-group library for pressurized water reactor (PWR) analysis, by comparing simulated results with measured data for critical experiments and operating PWRs. Uncertainties of the SCALE/Polaris–PARCS code procedure for PWR analysis were evaluated in the validation for the PWR key nuclear parameters such as critical boron concentrations, reactivity, control bank work, temperature coefficients, and pin and assembly power peaking factors.

Details

Language :
English
ISSN :
26734362
Volume :
5
Issue :
3
Database :
Directory of Open Access Journals
Journal :
Journal of Nuclear Engineering
Publication Type :
Academic Journal
Accession number :
edsdoj.8a28650397d04edc8c9896f0ae850c0f
Document Type :
article
Full Text :
https://doi.org/10.3390/jne5030017