Back to Search Start Over

Monitoring of surface cleaning and disinfection in a Brazilian pediatric unit

Authors :
Lucas de Oliveira Bernardes
Fernando Ribeiro dos Santos
Natália Liberato Norberto Angeloni
Mara Cristina Ribeiro Furlan
Larissa da Silva Barcelos
Adriano Menis Ferreira
Alvaro Francisco Lopes de Sousa
Denise de Andrade
Marília Duarte Valim
Odinea Maria Amorim Batista
Luís Velez Lapão
Aires Garcia dos Santos Junior
Helder de Pádua Lima
Source :
Therapeutic Advances in Infectious Disease, Vol 10 (2023)
Publication Year :
2023
Publisher :
SAGE Publishing, 2023.

Abstract

Background: Understanding the correlation between the methods of monitoring surface cleaning and disinfection (SCD) is fundamental for better infection control. Purpose: This study aims to correlate the SCD monitoring methods in a Brazilian pediatric unit. This is an exploratory, longitudinal, and correlational study. Methods: The study was conducted in a pediatric hospitalization unit of a medium-sized hospital from December 2020 to March 2021. Four high-contact surfaces were analyzed before and after the cleaning and disinfection process by means of visual inspection, quantification of adenosine triphosphate (ATP), and colony-forming unit (CFU) count. The study consisted of three stages: stage I involving situational diagnosis of the SCD process; stage II referring to the implementation of the Surface Cleaning and Disinfection Standardization Program (SCDSP); and stage III involving long-term assessment after implementing the program. A total of 192 assessments were performed in each stage, totaling 576 in the three study stages. Conclusions: A significant correlation was found between the ATP quantification methods and microbial count in the bed railing ( p = 0.009) and companion’s armchair ( p = 0.018) surfaces. In both cases, Spearman’s correlation coefficients were positive, indicating a positive correlation between ATP and microbial count scores, that is, the higher the ATP values (in RLUs), the greater the microbial counts (in CFUs/cm 2 ). The analysis of the ROC curves suggests that the surfaces presenting ATP below 108 RLUs can be considered approved. The ATP method yielded 78.6% sensitivity; in turn, microbial count presented a sensitivity of 85.7%. It is important to use different methods to monitor the cleaning and disinfection of surfaces, as each one has different sensitivity and specificity.

Details

Language :
English
ISSN :
2049937X and 20499361
Volume :
10
Database :
Directory of Open Access Journals
Journal :
Therapeutic Advances in Infectious Disease
Publication Type :
Academic Journal
Accession number :
edsdoj.8a043a2852f04300b957163b1ce51ac6
Document Type :
article
Full Text :
https://doi.org/10.1177/20499361221148007