Back to Search Start Over

Standardization of measurement of cervical elastography, its reproducibility, and analysis of baseline clinical factors affecting elastographic parameters

Authors :
Hyun-Joo Seol
Ji-Hee Sung
Won Joon Seong
Hyun Mi Kim
Hyun Soo Park
Hayan Kwon
Han-Sung Hwang
Yun Ji Jung
Ja-Young Kwon
Soo-young Oh
Source :
Obstetrics & Gynecology Science, Vol 63, Iss 1, Pp 42-54 (2020)
Publication Year :
2020
Publisher :
Korean Society of Obstetrics and Gynecology, 2020.

Abstract

ObjectiveTo provide a standardized protocol for the measurement of cervical strain elastography, present its reproducibility, and analyze baseline clinical factors affecting the measurement of elastographic parameters.MethodsThis study was performed by the Korean Research Group of Cervical Elastography. We enrolled pregnant women according to our study protocol. After measuring the cervical length, elastography was performed using the E-Cervix™ quantification tool to measure the strain of the cervix using intrinsic compression. We evaluated 5 elastographic parameters, namely, the strain of the internal os of the cervix (IOS), strain of the external os of the cervix (EOS), ratio of the strain of IOS and EOS, elasticity contrast index, and hardness ratio. For baseline clinical factors, we examined the maternal body mass index, blood pressure, heart rate, uterine artery Doppler indices, and fetal presentation.ResultsWe established a specific protocol for the measurement of cervical elastography using the E cervix program. For all elastographic parameters, the intra-observer intraclass correlation coefficient (ICC) ranged from 0.633 to 0.723 for single measures and from 0.838 to 0.887 for average measures, and the inter-observer ICC ranged from 0.814 to 0.977 for single measures and from 0.901 to 0.988 for average measures. Regression analysis showed that the measurement of the elastographic parameter was not affected by baseline clinical factors.ConclusionWe present a standardized protocol for the measurement of cervical elastography using intrinsic compression. According to this protocol, reproducibility was acceptable and the measurement of elastographic parameters was not affected by the baseline clinical factors studied.

Details

Language :
English, Korean
ISSN :
22878572 and 22878580
Volume :
63
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Obstetrics & Gynecology Science
Publication Type :
Academic Journal
Accession number :
edsdoj.88e7f76167284c53b2139a936ab41698
Document Type :
article
Full Text :
https://doi.org/10.5468/ogs.2020.63.1.42