Back to Search Start Over

Exploring Flexural Strength Variation in Polymeric Materials for Provisional Fixed Prosthetic Structures: Comparative Analysis with and without Reinforcement through Laboratory Experimentation and Statistical Evaluation

Authors :
Mariana Dimova-Gabrovska
Todor Uzunov
Angela Gusiyska
Dobromira Shopova
Iva Taneva
Ivan Gerdzhikov
Stefan Rangelov
Source :
Applied Sciences, Vol 14, Iss 9, p 3923 (2024)
Publication Year :
2024
Publisher :
MDPI AG, 2024.

Abstract

Provisional fixed partial dentures represent a critical phase in dental treatment, necessitating heightened mechanical durability, particularly in comprehensive and extended treatment plans. Strengthening these structures with various reinforcing materials offers a method to enhance their resilience. Utilizing a three-point testing methodology on standardized trial specimens allows for a comparative assessment of various materials and reinforcement techniques for pre-prosthetic applications. This study aims to validate and assess the significance of integrating different reinforcing materials into standardized test bodies. The study focuses on test specimens comprising three types of unreinforced laboratory and clinical polymers for provisional constructions (n = 6)—heat-cured PMMA (Superpont C+B, Spofa Dental, Czech Republic), CAD-CAM prefabricated PMMA (DD temp MED, Dental Direkt, Germany), CAD-CAM printing resin (Temporary CB Resin, FormLabs, USA), self-polymerizing PEMA (DENTALON plus, Kulzer, Germany), light-polymerizing composite (Revotek LC, GC, Japan), and dual-polymerizing composite (TempSpan, Pentron, USA). Additionally, laboratory polymers are evaluated in groups with five types of reinforcing filaments (n = 15)—Glass Fiber (Fiber Splint One-Layer, Polydentia, Switzerland), Polyethylene thread (Ribbond Regular 4.0 mm, Ribbond Inc., USA), triple-stranded chrome-cobalt wire for splinting 015″ (Leone S.p.a., Italy), Aesthetic ligature wire 012″ (Leone S.p.a., Italy), and Glass Fiber coated with light-cured composite 8.5 × 0.2 mm (Interlig, Angelus, Brazil). Analysis of the data using Generalized Linear Models (GLMs) reveals that the experimental bodies, produced via the subtractive digital method using PMMA (DD temp MED, Dental Direkt GmbH, Germany) as the polymer and glass filaments as the reinforcement, exhibit superior mechanical properties, particularly when pre-wetted with Interlig liquid composite (Angelus, Brazil).

Details

Language :
English
ISSN :
20763417
Volume :
14
Issue :
9
Database :
Directory of Open Access Journals
Journal :
Applied Sciences
Publication Type :
Academic Journal
Accession number :
edsdoj.875eedfbf3714067b7f77e185f27e050
Document Type :
article
Full Text :
https://doi.org/10.3390/app14093923