Reduction of the fluorine-18-labeled fluorodeoxyglucose dose for clinically dedicated breast positron emission tomography

Authors :
Yoko Satoh
Tetsuro Sekine
Yoshie Omiya
Hiroshi Onishi
Utaroh Motosugi
Source :
EJNMMI Physics, Vol 6, Iss 1, Pp 1-11 (2019)
Publication Year :
2019
Publisher :
SpringerOpen, 2019.

Abstract

Abstract Purpose To determine the clinically acceptable level of reduction in the injected fluorine-18 (18F)-labeled fluorodeoxyglucose (18F-FDG) dose in dedicated breast positron emission tomography (dbPET). Methods A breast phantom with four spheres exhibiting various diameters (5, 7.5, 10, and 16 mm), a background 18F-FDG radioactivity of 2.28 kBq/mL, and a sphere-to-background radioactivity ratio of 8:1 was used. True dose-reduced dbPET images were obtained by data acquisition for 20 min in list mode at multiple time points over 7 h of radioactive decay. Simulated dose-reduced images were generated by reconstruction with a portion of the list mode acquisition data. True and simulated dose-reduced images were visually and quantitatively compared. On the basis of the phantom study, dbPET images for 32 breasts of 28 women with abnormal uptake were generated after simulated reduction of the injected 18F-FDG doses; these images were compared with those acquired using current clinical doses. Results There were no qualitative differences between true and simulated dose-reduced phantom images. The phantom study revealed that the minimal required dose was 12.5% for the detection of 5-mm spheres and 25% for precise semi-quantification of FDG in the spheres. The 7-min reconstruction with a 100% dose was defined as the reference for the clinical study. The image quality and lesion conspicuity were clinically acceptable for the 25% dose images. Lesion detectability on the 12.5% dose images was maintained despite image quality degradation. Conclusions In summary, 25% of the standard 18F-FDG dose for dbPET can provide a clinically acceptable image quality, while 12.5% of the standard dose results in acceptable quality in terms of lesion detection when lesions are located at a sufficient distance from the edge of the dbPET detector.

Details

Language :
English
ISSN :
21977364
Volume :
6
Issue :
1
Database :
Directory of Open Access Journals
Journal :
EJNMMI Physics
Publication Type :
Academic Journal
Accession number :
edsdoj.86064e0ca6a64805b035f5f166871b21
Document Type :
article
Full Text :
https://doi.org/10.1186/s40658-019-0256-9