Back to Search Start Over

Coração carcinóide – a propósito de um caso clínico

Authors :
Ana Rita Santos
Bruno Stuart
Carlos Cotrim
Ana Rita Almeida
Paula Fazendas
Liliana Lopes
Inês Cruz
Hélder Pereira
Source :
Revista Portuguesa de Cardiologia, Vol 31, Iss 10, Pp 661-665 (2012)
Publication Year :
2012
Publisher :
Elsevier, 2012.

Abstract

Resumo: Os autores apresentam o caso de uma doente de 76 anos, com o diagnóstico de tumor neuroendócrino do cego desde 2004 com metastização hepática, e com síndrome carcinóide desde setembro de 2010. A doente realizou ciclos de quimioterapia de forma intermitente, pelo que manteve sintomas e agravamento das lesões secundárias. Desde junho de 2011 apresenta sinais e sintomas compatíveis com insuficiência cardíaca direita, ficando internada em setembro de 2011. Nesta sequência realizou ecocardiograma transtorácico bi e tridimensional que revelou cavidades direitas dilatadas e folhetos das válvulas tricúspide e pulmonar espessados, fixos, condicionando insuficiência tricúspide grave e estenose e insuficiência pulmonar ligeiras, sugestivas de doença carcinóide cardíaca. Os autores discutem a relevância clínica da ecocardiografia transtorácica, e, atualmente, da ecocardiografia tridimensional, como o método de investigação de escolha nestes casos, ao permitir avaliar de forma única as válvulas e o aparelho subvalvular. Abstract: We describe the case of a 76-year-old woman, diagnosed with a neuroendocrine tumor of the cecum in 2004, with liver metastases and carcinoid syndrome since September 2010. The patient had been treated intermittently with chemotherapy cycles, and remained symptomatic, with worsening secondary lesions. In June 2011 she began to present signs and symptoms of right heart failure and was hospitalized in September 2011. Transthoracic two- and three-dimensional echocardiography revealed enlarged right atrium and ventricle and thickened and fixed tricuspid and pulmonary valve leaflets, causing severe tricuspid regurgitation and mild pulmonary regurgitation and stenosis, suggestive of carcinoid heart disease. The authors discuss the clinical importance of transthoracic echocardiography, and the more recent three-dimensional echocardiography, as the diagnostic exam of choice in these cases, as it is especially suitable for assessing the valves and subvalvular apparatus. Palavras-chave: Doença carcinóide cardíaca, Ecocardiografia transtorácica, Ecocardiografia tridimensional, Keywords: Carcinoid heart disease, Transthoracic echocardiography, Three-dimensional echocardiography

Details

Language :
English, Portuguese
ISSN :
08702551
Volume :
31
Issue :
10
Database :
Directory of Open Access Journals
Journal :
Revista Portuguesa de Cardiologia
Publication Type :
Academic Journal
Accession number :
edsdoj.85e46cc96aa4789a375ea58d8b4c6f2
Document Type :
article
Full Text :
https://doi.org/10.1016/j.repc.2012.01.020