Back to Search Start Over

Comparison of effects of mydriatic drops (1% cyclopentolate and 0.5% tropicamide) on anterior segment parameters

Authors :
Yelda Yildiz Tasci
Nilufer Yesilirmak
Sema Yuzbasioglu
Demet Ozdas
Berke Temel
Source :
Indian Journal of Ophthalmology, Vol 69, Iss 7, Pp 1802-1807 (2021)
Publication Year :
2021
Publisher :
Wolters Kluwer Medknow Publications, 2021.

Abstract

Purpose: The purpose of this study is to investigate and compare the effects of cyclopentolate and tropicamide drops on anterior segment parameters in healthy individuals. Methods: Two hundred and fifty-eight eyes of 129 healthy volunteers were included in this randomized clinical study. Cyclopentolate 1% drop was applied to 75 (58%) participants (group 1) and tropicamide 0.5% drop was applied to 54 (42%) participants (group 2). Flat keratometry (K1), steep keratometry (K2), axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), white-to-white (WTW) distance, pupil diameter, total pupil offset and intraocular lens (IOL) power were measured before and after drops, using Lenstar 900 optical biometry. Results: The increase in CCT, ACD, pupil diameter, and pupil offset was significant in group 1 after the drop (P < 0.05), while the increase in ACD, pupil diameter, and pupil offset was significant in group 2 (P < 0.05). When the two groups were compared, there was no significant difference in K1, K2, CCT, ACD, WTW, pupil diameter, pupil offset, and IOL power (using Sanders–Retzlaff–Kraff T formula) changes after drops (P > 0.05), whereas the change in AL was significant (P = 0.01). Conclusion: The effects of cyclopentolate and tropicamide drops on anterior segment parameters were similar; they did not make significant changes in K1, K2, AL, WTW, and third-generation IOL power calculation. However, ACD values significantly changed after these drops; thus, measuring anterior segment parameters before mydriatic agents should be taken into account particularly for fourth-generation IOL formulas and phakic IOL implantation. The change in pupil offset, which can be important in excimer laser and multifocal IOL applications, was not clinically significant.

Details

Language :
English
ISSN :
03014738 and 19983689
Volume :
69
Issue :
7
Database :
Directory of Open Access Journals
Journal :
Indian Journal of Ophthalmology
Publication Type :
Academic Journal
Accession number :
edsdoj.85c78d60c19b47448521295da8a83f7c
Document Type :
article
Full Text :
https://doi.org/10.4103/ijo.IJO_2677_20