Back to Search Start Over

Abstract Number ‐ 43: Flow Diversion for Intracranial Aneurysms in Large Caliber Vessels: A Case Series

Authors :
Juan Vivanco‐Suarez
Mudassir Farooqui
Aaron Rodriguez‐Calienes
Ajay K Wakhloo
Margarita Rabinovich
Mohamed Abouelleil
David Altschul
Chaim Feigen
Johanna T Fifi
Stavros Matsoukas
Fawaz Al‐Mufti
Milagros Galecio‐Castillo
Justin A Singer
Santiago Ortega‐Gutierrez
Source :
Stroke: Vascular and Interventional Neurology, Vol 3, Iss S1 (2023)
Publication Year :
2023
Publisher :
Wiley, 2023.

Abstract

Introduction The safe and effective profile of flow diverters (FD) has allowed neuro‐interventionalists to consider them as a versatile tool for the treatment of aneurysms with different morphologies, locations, and characteristics. Optimal deployment with complete wall apposition affects FD performance. However, few devices are suitable for aneurysms in large caliber vessels. Herein, we aimed to describe the safety and efficacy of a large caliber (5 mm) FD for the treatment of intracranial aneurysms. Methods We performed a retrospective, multi‐center cohort study of adult patients in whom a 5 mm Surpass Streamline FD was implanted between 2018 and 2021 in the United States. Efficacy outcome was complete occlusion at final follow‐up. Safety outcomes were ischemic/hemorrhagic events and mortality up to 30 days following the procedure. Secondary safety was assessed by the rate of adjunctive devices/treatments to overcome technical complications and improve wall apposition. Results A total of 29 patients harboring 29 aneurysms were treated with 39 FDs (36 large‐diameter devices). Mean age was 57.8 ± 15.7 years. Aneurysm morphologies were saccular (n = 15), pseudoaneurysm (n = 7), fusiform (n = 6), and dissecting (n = 1). Locations were internal carotid artery (ICA) petro‐cavernous segment (n = 15), ICA paraophthalmic (n = 5), ICA cervical (n = 4), basilar artery (n = 3), and vertebral artery (n = 2). Aneurysm size mean was 11.4 ± 6.7 mm, and neck size mean 6.5 ± 3.9 mm. Proximal FD landing zone vessel diameter was 4.8 ± 1.3 mm and distal 4.5 ± 1.2 mm. At a mean final follow‐up of 12 ± 6 months, 18 (65%) aneurysms were completely occluded. Ischemic/hemorrhagic events occurred in 2 (7%), and 1 patient died during hospitalization. Balloon‐assisted angioplasty was performed in 19 (66%) cases, adjunctive stenting in 8 (28%), and coiling in 1 (3%). Patients who received an adjunctive device/treatment had an 82% (14/17) complete occlusion compared to 66% (4/6) in those who did not. Conclusions The use of large caliber FDs to treat complex intracranial aneurysms located in large‐diameter dysplastic vessels is technically feasible and safe. The use of adjunctive devices and techniques to achieve optimal wall apposition seems crucial to optimize treatment outcomes. Comparative studies with devices specially designed for this patient population might provide further insights into the best device selection.

Details

Language :
English
ISSN :
26945746
Volume :
3
Issue :
S1
Database :
Directory of Open Access Journals
Journal :
Stroke: Vascular and Interventional Neurology
Publication Type :
Academic Journal
Accession number :
edsdoj.85b7fb148e4f4073b0ca226eceac61c5
Document Type :
article
Full Text :
https://doi.org/10.1161/SVIN.03.suppl_1.043