Direct Measurements of the Volume Flow Rate and Emissions in a Large Naturally Ventilated Building

Authors :
David Janke
Qianying Yi
Lars Thormann
Sabrina Hempel
Barbara Amon
Štěpán Nosek
Philippe van Overbeke
Thomas Amon
Source :
Sensors, Vol 20, Iss 21, p 6223 (2020)
Publication Year :
2020
Publisher :
MDPI AG, 2020.

Abstract

The direct measurement of emissions from naturally ventilated dairy barns is challenging due to their large openings and the turbulent and unsteady airflow at the inlets and outlets. The aim of this study was to quantify the impacts of the number and positions of sensors on the estimation of volume flow rate and emissions. High resolution measurements of a naturally ventilated scaled building model in an atmospheric boundary layer wind tunnel were done. Tracer gas was released inside the model and measured at the outlet area, using a fast flame ionization detector (FFID). Additionally, the normal velocity on the area was measured using laser Doppler anemometry (LDA). In total, for a matrix of 65 × 4 sensor positions, the mean normal velocities and the mean concentrations were measured and used to calculate the volume flow rate and the emissions. This dataset was used as a reference to assess the accuracy while systematically reducing the number of sensors and varying the positions of them. The results showed systematic errors in the emission estimation up to +97%, when measurements of concentration and velocity were done at one constant height. This error could be lowered under 5%, when the concentrations were measured as a vertical composite sample.

Details

Language :
English
ISSN :
14248220
Volume :
20
Issue :
21
Database :
Directory of Open Access Journals
Journal :
Sensors
Publication Type :
Academic Journal
Accession number :
edsdoj.852541d5bc114291a861051e233a10ff
Document Type :
article
Full Text :
https://doi.org/10.3390/s20216223