Back to Search
Start Over
Removal of a Hickman catheter using a laser sheath
- Source :
- Journal of Arrhythmia, Vol 35, Iss 1, Pp 158-160 (2019)
- Publication Year :
- 2019
- Publisher :
- Wiley, 2019.
-
Abstract
- Abstract A 31‐year‐old female with 10 years indwelled Hickman catheter for idiopathic pulmonary hypertension presented infectious findings. We decided to remove it but simple traction did not work. Although it was an off labeled use, we could remove it using a laser sheath and snare technique without any complication.
Details
- Language :
- English
- ISSN :
- 18832148 and 18804276
- Volume :
- 35
- Issue :
- 1
- Database :
- Directory of Open Access Journals
- Journal :
- Journal of Arrhythmia
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.82e686cca7704fb28245fe5d5b9e5dd8
- Document Type :
- article
- Full Text :
- https://doi.org/10.1002/joa3.12147