Optimization of the regularization parameter in the Dual Annealing method used for the reconstruction of energy spectrum of electron beam generated by the AQURE mobile accelerator

Authors :
Adam Ryczkowski
Tomasz Piotrowski
Marcin Staszczak
Marcin Wiktorowicz
Przemysław Adrich
Source :
Zeitschrift für Medizinische Physik, Vol 34, Iss 4, Pp 510-520 (2024)
Publication Year :
2024
Publisher :
Elsevier, 2024.

Abstract

Introduction: The shape of the energy spectrum is an essential component of any electron beam Monte Carlo model. Due to specialized equipment and the long measurement time for the direct methods for determining the energy spectrum, attractive alternatives are backward spectrum reconstructions from the measured data. One such approach is solving the first-degree Fredholm integral equation with appropriate regularization. It makes it possible to calculate the depth distribution as the sum of the distributions from monoenergetic beams. This study aims to determine the optimal value of the regularization parameter for the problem of determining the spectrum of the electron beam produced by a mobile accelerator used during intraoperative radiotherapy. Material and methods: The Geant4 package was used to generate the distributions of deep doses for monoenergetic beams for two models with different degrees of complexity, i.e. simple (theoretical) and full (for the mobile accelerator). The dose distributions for four different shapes of energy spectrum (for each model) were obtained similarly. They were established as the reference data for further calculations. The Dual Annealing optimization method was used to obtain the reconstructed spectrum. The multiple optimizations that differ by the regularization parameter (ranging from 0 to 1) were performed. For each reconstruction, similarity indicators of the energy spectrum and the dose distribution to the referenced data were calculated to determine the optimal regularization parameters. Results: Optimal regularization parameters determined by similarity indicators for the spectrum and the dose distribution differ for geometry models considered in the study. The regularization parameter for the simple geometry ranged from 0.03 to 0.05, while for full geometry, they were from 0.05 to 0.06. The results for conventional linear accelerators found in the literature range from 0.5 to 1.1. Conclusion: The Dual Annealing optimization method can be effectively used to solve the Fredholm equation with Tikhonov regularization to reconstruct an electron beam's energy spectrum. The regularization parameter value depends on the beam-forming system. Its value for the mobile accelerator considered in the study ranges from 0.05 to 0.06, depending on the nominal beam energy value.

Details

Language :
English
ISSN :
09393889
Volume :
34
Issue :
4
Database :
Directory of Open Access Journals
Journal :
Zeitschrift für Medizinische Physik
Publication Type :
Academic Journal
Accession number :
edsdoj.822668c62b3b4d27a3a5c6ebb132e4be
Document Type :
article
Full Text :
https://doi.org/10.1016/j.zemedi.2023.03.003