Back to Search Start Over

Mechanical Complications of Proximal Femur Fractures Treated with Intramedullary Nailing: A Retrospective Study

Authors :
Alvaro Lopez-Hualda
Esperanza Marin García-Cabrera
Marina Lobato-Perez
Javier Martinez-Martin
Giacomo Rossettini
Massimiliano Leigheb
Jorge Hugo Villafañe
Source :
Medicina, Vol 60, Iss 5, p 718 (2024)
Publication Year :
2024
Publisher :
MDPI AG, 2024.

Abstract

Background and Objectives: This retrospective cohort study analyzes mechanical complications in hip fracture surgery using the Trochanteric Fixation Nail-Advanced (TFNA) implant. It investigates the correlation of these complications with demographic, intraoperative, and radiological factors, aiming to identify associated risk factors and suggest improvements in clinical surveillance and treatment strategies. Materials and Methods: We enrolled 253 patients diagnosed with pertrochanteric hip fractures treated between 2017 and 2021, with 126 meeting the criteria for a minimum 6-month follow-up. Data on demographics, American Anesthesia Association Classification (ASA), comorbidities, AO/OTA [AO (Arbeitsgemeinschaft für Osteosynthesefragen)/OTA (Orthopedic Trauma Association)] fracture classification, procedural details, and time to failure were collected. Radiographs were evaluated for reduction quality, the tip–apex distance (TAD), progressive varus deviation, and identification of mechanical complications. Statistical analysis was performed using SPSS software. Results: The predominant AO/OTA fracture classification was 31A2 in 67 cases (52.7%). Reduction quality was deemed good or acceptable in 123 cases (97.6%). The mean time to failure was 4.5 months (range: 2.2–6). The average TAD was 18 mm (range: 1.2–36), with a mean progressive varus deviation of 2.44° (range: 1.30–4.14). A good or acceptable reduction quality was observed in 97.6% of cases. Mechanical complications occurred in 21.4% of patients, with significant associations found with the lateral cortex fracture, use of a TFNA implant with a 130° angle, open reduction, and absence of prior osteoporosis treatment. Conclusions: The study provides insights into mechanical complications in proximal femur fractures treated with the TFNA nail, emphasizing the need for enhanced clinical and radiographic surveillance, especially in patients without osteoporosis treatment. Our findings support the necessity for further clinical studies comparing these outcomes with other implant designs and underscore the importance of personalized treatment strategies to reduce complication rates.

Details

Language :
English
ISSN :
16489144 and 1010660X
Volume :
60
Issue :
5
Database :
Directory of Open Access Journals
Journal :
Medicina
Publication Type :
Academic Journal
Accession number :
edsdoj.80f19b014e143078273ec02d0007273
Document Type :
article
Full Text :
https://doi.org/10.3390/medicina60050718