Back to Search Start Over

Clinical experience with 18F-JK-PSMA-7 when using a digital PET/CT

Authors :
Irina Vierasu
Nicola Trotta
Simone Albisinni
Céline Mathey
Gil Leurquin-Sterk
Simon Lacroix
Gaetan Van Simaeys
Thierry Quackels
Thierry Roumeguère
Serge Goldman
Source :
European Journal of Hybrid Imaging, Vol 6, Iss 1, Pp 1-10 (2022)
Publication Year :
2022
Publisher :
SpringerOpen, 2022.

Abstract

Abstract Background Digital PET/CT systems make use of a new technology with higher sensitivity and other better technological features than the analog ones. They require adaptation of the trade-off between performance, tracer dose and acquisition time. The aim of the study was to explore the performance of 18F-JK-PSMA-7 imaging when performed on a digital PET/CT with an adapted protocol, in a population of patients with prostate cancer patients (PCa). Influence of previous therapy on PET/CT performance is generally disregarded in PSMA-based imaging, despite potential influence of hormono-chemotherapy on the target expression. This potential influence was also tested in this work. Methods A total of 54 PCa patients experiencing biochemical recurrence were included in the study, in which we analysed the diagnostic performance of digital 18F-JK-PSMA-7 PET/CT. Compared to our protocol applied for acquisition on an analog system, administered dose and acquisition time were reduced by 20% and 50% respectively. We specifically took into consideration the influence of previous treatments on recurrence detection. Results We detected overall 18F-JK-PSMA-7-positive lesions in 38/54 patients (70.3%). There was no statistically significant difference regarding the detection rate between the groups of patients who had hormono-chemotherapy any time after initial diagnosis and those who never got any hormonal or chemotherapeutic treatment. Regarding the SUV max values, there was not significant difference between the two groups of patients neither in pelvic ganglions nor in other metastatic sites or the prostate region. Conclusion 18F-JK-PSMA7 PET/CT with administered dose and acquisition time adapted to the digital technology provides valuable information in PCa patients with biochemical recurrence.

Details

Language :
English
ISSN :
25103636
Volume :
6
Issue :
1
Database :
Directory of Open Access Journals
Journal :
European Journal of Hybrid Imaging
Publication Type :
Academic Journal
Accession number :
edsdoj.80ea8759d77543fcb89478c156de2d17
Document Type :
article
Full Text :
https://doi.org/10.1186/s41824-022-00128-3