Ascorbic Acid Sensing by Molecularly Imprinted Electrosynthesized Polymer (e-MIP) on Screen-Printed Electrodes

Authors :
Giancarla Alberti
Camilla Zanoni
Lisa Rita Magnaghi
Raffaela Biesuz
Source :
Chemosensors, Vol 11, Iss 6, p 348 (2023)
Publication Year :
2023
Publisher :
MDPI AG, 2023.

Abstract

This paper presents the development of a cheap and rapid electrochemical sensor for ascorbic acid detection. In particular, the graphite ink working electrode of screen-printed cells was covered by a film of elecrosynthesized molecularly imprinted polypyrrole (e-MIP); differential pulse voltammetry (DPV) was the selected method for the analyte detection. The ascorbic acid molecules were successfully entrapped in the polypyrrole film, creating the recognition sites. The best results were obtained after polypyrrole overoxidation and performing the measurements in phosphate buffer solution 0.05 M/KCl 0.1 M at pH 7.5. A comparison with the bare and the not-imprinted polypyrrole-modified electrodes showed that the e-MIP-based sensor had the highest selectivity and reproducibility. The developed method was applied to assess ascorbic acid in farmaceutical products, obtaining values not significantly different from the declared content.

Details

Language :
English
ISSN :
22279040
Volume :
11
Issue :
6
Database :
Directory of Open Access Journals
Journal :
Chemosensors
Publication Type :
Academic Journal
Accession number :
edsdoj.7f73972a749f98f74577177ab160a
Document Type :
article
Full Text :
https://doi.org/10.3390/chemosensors11060348