Back to Search
Start Over
Quantitative Magnetic Resonance Imaging Analysis of the Cervical Spine Extensor Muscles: Intrarater and Interrater Reliability of a Novice and an Experienced Rater
- Source :
- Asian Spine Journal, Vol 12, Iss 1, Pp 94-102 (2018)
- Publication Year :
- 2018
- Publisher :
- Korean Spine Society, 2018.
-
Abstract
- Study DesignReliability study.PurposeTo examine the reliability of novice and experienced raters for measurements of the size and composition of the cervical extensor muscles using a thresholding technique.Overview of LiteratureAlthough some authors have reported on the dependability of magnetic resonance imaging (MRI) measurements of the cervical muscles, there remains some variability regarding intrarater and interrater reliabilities, and few studies have examined the associated measurement error. Whether the rater's experience noticeably influences the reliability and precision of such measurements has also not been examined.MethodsA sample of 10 patients with cervical pathologies was selected. Muscle cross-sectional area (CSA), functional cross-sectional area (FCSA), and signal intensity of the cervical extensor muscles were acquired from axial T2-weighted MRIs by a novice and an experienced rater. All measurements were obtained twice, at least 5 days apart, while the raters were blinded to all earlier measurements.ResultsInterrater reliability estimates (intraclass correlation coefficients) varied between 0.84 and 0.99 for the novice rater and between 0.94 and 0.99 for the experienced rater, indicating excellent reliability. The standard error of measurement for the novice rater was, however, noticeably higher for all cervical muscle measurements. Most of the interrater estimates showed excellent agreement with the exception of CSA measurement of the semispinalis cervicis at C4–C7 and FCSA measurement of the multifidus and semispinalis cervicis at C4–C7, which showed poor interrater reliability.ConclusionsThe proposed method of investigating cervical muscle measurements was highly reliable; however, novice raters should receive adequate training before using this method for diagnostic, research, and clinical purposes.
Details
- Language :
- English
- ISSN :
- 19761902 and 19767846
- Volume :
- 12
- Issue :
- 1
- Database :
- Directory of Open Access Journals
- Journal :
- Asian Spine Journal
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.7f5aab3cb74a4c67acad42a9dc576a50
- Document Type :
- article
- Full Text :
- https://doi.org/10.4184/asj.2018.12.1.94