Back to Search Start Over

Usefulness of Real-Time Quantitative Microvascular Ultrasonography for Differentiation of Graves’ Disease from Destructive Thyroiditis in Thyrotoxic Patients

Authors :
Han-Sang Baek
Ji-Yeon Park
Chai-Ho Jeong
Jeonghoon Ha
Moo Il Kang
Dong-Jun Lim
Source :
Endocrinology and Metabolism, Vol 37, Iss 2, Pp 323-332 (2022)
Publication Year :
2022
Publisher :
Korean Endocrine Society, 2022.

Abstract

Background Microvascular ultrasonography (MVUS) is a third-generation Doppler technique that was developed to increase sensitivity compared to conventional Doppler. The purpose of this study was to compare MVUS with conventional color Doppler (CD) and power Doppler (PD) imaging to distinguish Graves’ disease (GD) from destructive thyroiditis (DT). Methods This prospective study included 101 subjects (46 GDs, 47 DTs, and eight normal controls) from October 2020 to November 2021. All ultrasonography examinations were performed using microvascular flow technology (MV-Flow). The CD, PD, and MVUS images were semi-quantitatively graded according to blood flow patterns. On the MVUS images, vascularity indices (VIs), which were the ratio (%) of color pixels in the total grayscale pixels in a defined region of interest, were obtained automatically. Receiver operating characteristic curve analysis was performed to verify the diagnostic performance of MVUS. The interclass correlation coefficient and Cohen’s kappa analysis were used to analyze the reliability of MVUS (ClinicalTrials.gov:NCT04879173). Results The area under the curve (AUC) for CD, PD, MVUS, and MVUS-VI was 0.822, 0.844, 0.808, and 0.852 respectively. The optimal cutoff value of the MVUS-VI was 24.95% for distinguishing GD and DT with 87% sensitivity and 80.9% specificity. We found a significant positive correlation of MVUS-VI with thyrotropin receptor antibody (r=0.554) and with thyroid stimulating immunoglobulin bioassay (r=0.841). MVUS showed high intra- and inter-observer reliability from various statistical method. Conclusion In a real time and quantitative manner, MVUS-VI could be helpful to differentiate GD from thyroiditis in thyrotoxic patients, with less inter-observer variability.

Details

Language :
English, Korean
ISSN :
2093596X and 20935978
Volume :
37
Issue :
2
Database :
Directory of Open Access Journals
Journal :
Endocrinology and Metabolism
Publication Type :
Academic Journal
Accession number :
edsdoj.7e5a189569424369ac89027fe4d646ca
Document Type :
article
Full Text :
https://doi.org/10.3803/EnM.2022.1413