Reliability and minimal detectable change of the ‘Imperial Spine’ marker set for the evaluation of spinal and lower limb kinematics in adults

Authors :
J. A. Deane
E. Papi
A. T. M. Phillips
A. H. McGregor
Source :
BMC Research Notes, Vol 13, Iss 1, Pp 1-8 (2020)
Publication Year :
2020
Publisher :
BMC, 2020.

Abstract

Abstract Objectives As a step towards the comprehensive evaluation of movement in patients with low back pain, the aim of this study is to design a marker set (three rigid segment spine, pelvic and lower limb model) and evaluate the reliability and minimal detectable change (MDC) of this marker set in healthy adults during gait and sit to stand (STS) tasks using three dimensional motion capture. Results The ‘Imperial Spine’ marker set was used to assess relative peak angles during gait and STS tasks using the minimum recommended sample size (n = 10) for reliability studies with minimum Intraclass Correlation Coefficient (ICC) of 0.70, optimum ICC 0.90 and 9 trials replicated per subject per task. Intra- and inter-tester reliability between an experienced and inexperienced user was examined. ICC, mean, standard error (SEM), Bland Altman 95% limits of agreement (LOA) and MDC were computed. ICC values demonstrated excellent intra- and inter-tester reliability in both tasks, particularly in the sagittal plane (majority ICCs > 0.80). SEM measurements were lower in gait (0.8–5.5°) than STS tasks (1°-12.6°) as were MDC values. LOA demonstrated good agreement. The ‘Imperial Spine’ marker set is reliable for use in healthy adults during functional tasks. Future evaluation in patients is required.

Details

Language :
English
ISSN :
17560500
Volume :
13
Issue :
1
Database :
Directory of Open Access Journals
Journal :
BMC Research Notes
Publication Type :
Academic Journal
Accession number :
edsdoj.7903eed40e3746bfbbbcb6911bd7cc9f
Document Type :
article
Full Text :
https://doi.org/10.1186/s13104-020-05295-9