Back to Search Start Over

Tip bendable suction ureteral access sheath versus traditional sheath in retrograde intrarenal stone surgery: an international multicentre, randomized, parallel group, superiority studyResearch in context

Authors :
Wei Zhu
Shusheng Liu
Jianwei Cao
Hao Wang
Hui Liang
Kehua Jiang
Yu Cui
Chu Ann Chai
Emre Burak Sahinler
Albert Aquino
Giorgio Mazzon
Wen Zhong
Zhijian Zhao
Lin Zhang
Jie Ding
Qing Wang
Yizhou Wang
Kelven Weijing Chen
Yongda Liu
Simon Choong
Kemal Sarica
Guohua Zeng
Source :
EClinicalMedicine, Vol 74, Iss , Pp 102724- (2024)
Publication Year :
2024
Publisher :
Elsevier, 2024.

Abstract

Summary: Background: Retrograde intrarenal surgery (RIRS) is the main treatments for upper urinary tract stones. The Ureteral Access Sheath (UAS) serves as a supplementary tool, facilitating direct kidney access during RIRS. High quality of evidence comparing tip bendable suction ureteral access sheath (S-UAS) with traditional UAS in RIRS for the treatment of renal and ureteral stones is lacking. The purpose of the study is to compare the efficacy and safety of S-UAS with traditional UAS in RIRS for the treatment of renal or ureteral stones ≤30 mm. Methods: An international, multicenter, and superiority randomized controlled trial included 320 intention-to-treat patients across 8 medical centers in China, the Philippines, Malaysia and Turkey from August 2023 to February 2024. The inclusion criteria were patients ≥18 years old with renal or ureteral stones ≤30 mm. RIRS was performed using either S-UAS or traditional UAS. The primary outcome was the immediately stone-free rate (SFR). Secondary outcomes included SFR 3 months after operation, operating time, hospital stay, auxiliary procedures, complications (using the Clavien–Dindo grading system), and improvement in the Quality of Life (QoL) score. Differences between proportions [risk difference (RD)]/means [mean difference (MD)] and 95% confidence intervals (CI) were presented. This study is registered at ClinicalTrials.gov: NCT05952635. Findings: The S-UAS group demonstrated a significantly higher immediately SFR (81.3% versus 49.4%; RD 31.9%; 95% CI 22.5%–41.7%; p = 0.004) compared to the traditional UAS group, as determined by the one-side superiority test. Additionally, the S-UAS group exhibited a higher SFR at 3 months post-operation (87.5% versus 70.0%; RD 17.5%; 95% CI 8.7%–26.3%; p

Details

Language :
English
ISSN :
25895370 and 91426995
Volume :
74
Issue :
102724-
Database :
Directory of Open Access Journals
Journal :
EClinicalMedicine
Publication Type :
Academic Journal
Accession number :
edsdoj.7736ba73a864497b5b2c9142699533c
Document Type :
article
Full Text :
https://doi.org/10.1016/j.eclinm.2024.102724