Back to Search
Start Over
A Preliminary Study on the Feasibility of the Quantitative Parameters of Dual-Energy Computed Tomography Enterography in the Assessment of the Activity of Intestinal Crohn’s Disease
- Source :
- International Journal of General Medicine, Vol Volume 14, Pp 7051-7058 (2021)
- Publication Year :
- 2021
- Publisher :
- Dove Medical Press, 2021.
-
Abstract
- Wei-xiong Xiao,&ast; Yu-ting Zhu,&ast; Zhi-chao Zhang, Min Luo, Ming-ping Ma Department of Radiology, Fujian Provincial Hospital, Provincial Clinical College of Fujian Medical University, Fuzhou, People’s Republic of China&ast;These authors contributed equally to this workCorrespondence: Min Luo; Ming-ping MaDepartment of Radiology, Fujian Provincial Hospital, Provincial Clinical College of Fujian Medical University, No. 134 East Street, Gulou District, Fuzhou, 350001, People’s Republic of ChinaTel +86 59187557768Email radiodrluo@163.comObjective: To investigate the value of dual energy CT enterography (DECTE) in evaluating the activity of Crohn’s disease (CD).Methods: The endoscopy and imaging data of 29 patients with CD confirmed by clinic and pathology were analyzed retrospectively. The clinical CD activity index (CDAI) was used as the disease activity grouping standard, 29 patients with CD were grouped into activity groups, 18 patients in the active group (CDAI ≥ 150) with 36 intestinal segments, and 11 patients in the remission group (CDAI < 150) with 20 intestinal segments.The virtual single energy CT value, slope of energy spectrum curve and iodine content were analyzed to evaluate the evaluation of intestinal CD activity by DECTE.Results: There were statistically significant differences in virtual single energy CT value (except 90 keV and 100 keV virtual single energy CT value), curve slope and iodine content between remission group and active group (P < 0.05), and has more diagnostic value for active phase (AUC > 0.5). ① Virtual single energy CT value: the AUC of 60 keV in arterial phase was the highest (0.924). The specificity of diagnosing CD in active stage was high (95%). ② Curve slope: the AUC of portal vein phase was the largest (0.731). The specificity of diagnosing CD in active stage was higher (85%). ③ Iodine content: the AUC of arterial phase was the highest (0.885). The specificity of diagnosing CD lesions in the active stage was 100%.Conclusion: The virtual single energy CT value, energy spectrum curve slope and iodine content can provide reference for clinical accurate diagnosis of CD activity.Keywords: Crohn’s disease, computed tomography, dual energy CT, virtual single
Details
- Language :
- English
- ISSN :
- 11787074
- Volume :
- ume 14
- Database :
- Directory of Open Access Journals
- Journal :
- International Journal of General Medicine
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.76fbcae0275246c0a9b43affe9720858
- Document Type :
- article