Back to Search Start Over

The Biological Activity of Fragmented Computer-Aided Design/Manufacturing Dental Materials before and after Exposure to Acidic Environment

Authors :
Codruța Eliza Ille
Elena-Alina Moacă
Maria Suciu
Lucian Barbu-Tudoran
Meda-Lavinia Negruțiu
Anca Jivănescu
Source :
Medicina, Vol 59, Iss 1, p 104 (2023)
Publication Year :
2023
Publisher :
MDPI AG, 2023.

Abstract

Three ceramic and composite computer-aided design/computer-aided manufacturing (CAD/CAM) materials from different manufacturers (Cerasmart (CS)—nanoceramic resin; Straumann Nice (SN)—glass ceramic and Tetric CAD (TC)—composite resin) were tested to investigate the biocompatibility and sustainability on human fibroblasts and keratinocytes cells. Each type of CAD/CAM blocks restorative materials with fine and rough surfaces was exposed to an acidic environment for one month. After that, various powders were obtained by milling. In parallel, powders were also prepared from each restorative material, which were not exposed to the acidic environment. The cytotoxic effects were investigated by means of MTT and LDH assays, as well as nitric oxide production on two human normal cell lines, namely, fibroblasts (BJ) and keratinocytes (HaCaT). In addition, the degree of adhesion of fibroblast cells to each CAD/CAM material was evaluated by scanning electron microscopy (SEM). The results showed that the two samples that were exposed to an acidic environment (CS and SN) induced a reduction of mitochondrial activity and plasma membrane damage as regards the fibroblast cells. A similar effect was observed in TC_fine-exposed material, which seemed to induce necrosis at the tested concentration of 1 mg/mL. No oxidative stress was observed in fibroblasts and keratinocytes treated with the CAD/CAM materials. Regarding the adhesion degree, it was found that the fibroblasts adhere to all the occlusal veneers tested, with the mention that the CS and SN materials have a weaker adhesion with fewer cytoplasmic extensions than TC material. With all of this considered, the CAD/CAM restorative materials tested are biocompatible and represent support for the attachment and dispersion of cells.

Details

Language :
English
ISSN :
16489144 and 1010660X
Volume :
59
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Medicina
Publication Type :
Academic Journal
Accession number :
edsdoj.76cded9ca5a64893b4e6f3d3fdf82946
Document Type :
article
Full Text :
https://doi.org/10.3390/medicina59010104